APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 11 of 26)
ADDRESS
FLEXANALOG NAME
7696
SRC 2 Demand Ia
7698
SRC 2 Demand Ib
7700
SRC 2 Demand Ic
7702
SRC 2 Demand Watt
7704
SRC 2 Demand var
7706
SRC 2 Demand Va
7712
SRC 3 Demand Ia
7714
SRC 3 Demand Ib
7716
SRC 3 Demand Ic
7718
SRC 3 Demand Watt
7720
SRC 3 Demand var
7722
SRC 3 Demand Va
7728
SRC 4 Demand Ia
7730
SRC 4 Demand Ib
7732
SRC 4 Demand Ic
7734
SRC 4 Demand Watt
7736
SRC 4 Demand var
7738
SRC 4 Demand Va
7744
SRC 5 Demand Ia
7746
SRC 5 Demand Ib
7748
SRC 5 Demand Ic
7750
SRC 5 Demand Watt
7752
SRC 5 Demand var
7754
SRC 5 Demand Va
7760
SRC 6 Demand Ia
7762
SRC 6 Demand Ib
7764
SRC 6 Demand Ic
7766
SRC 6 Demand Watt
7768
SRC 6 Demand var
7770
SRC 6 Demand Va
8672
Brk 1 Arc Amp A
8674
Brk 1 Arc Amp B
8676
Brk 1 Arc Amp C
8678
Brk 1 Op Time A
8679
Brk 1 Op Time B
8680
Brk 1 Op Time C
8681
Brk 1 Op Time
8682
Brk 2 Arc Amp A
8684
Brk 2 Arc Amp B
8686
Brk 2 Arc Amp C
8688
Brk 2 Op Time A
8689
Brk 2 Op Time B
8690
Brk 2 Op Time C
8691
Brk 2 Op Time
8692
Brk 3 Arc Amp A
8694
Brk 3 Arc Amp B
GE Multilin
UNITS
DESCRIPTION
Amps
Source 2 phase A current demand
Amps
Source 2 phase B current demand
Amps
Source 2 phase C current demand
Watts
Source 2 real power demand
Vars
Source 2 reactive power demand
VA
Source 2 apparent power demand
Amps
Source 3 phase A current demand
Amps
Source 3 phase B current demand
Amps
Source 3 phase C current demand
Watts
Source 3 real power demand
Vars
Source 3 reactive power demand
VA
Source 3 apparent power demand
Amps
Source 4 phase A current demand
Amps
Source 4 phase B current demand
Amps
Source 4 phase C current demand
Watts
Source 4 real power demand
Vars
Source 4 reactive power demand
VA
Source 4 apparent power demand
Amps
Source 5 phase A current demand
Amps
Source 5 phase B current demand
Amps
Source 5 phase C current demand
Watts
Source 5 real power demand
Vars
Source 5 reactive power demand
VA
Source 5 apparent power demand
Amps
Source 6 phase A current demand
Amps
Source 6 phase B current demand
Amps
Source 6 phase C current demand
Watts
Source 6 real power demand
Vars
Source 6 reactive power demand
VA
Source 6 apparent power demand
2
Breaker 1 arcing amp phase A
kA
-cyc
Breaker 1 arcing amp phase B
2
kA
-cyc
2
Breaker 1 arcing amp phase C
kA
-cyc
ms
Breaker 1 operating time phase A
ms
Breaker 1 operating time phase B
ms
Breaker 1 operating time phase C
ms
Breaker 1 operating time
Breaker 2 arcing amp phase A
2
kA
-cyc
Breaker 2 arcing amp phase B
2
kA
-cyc
Breaker 2 arcing amp phase C
2
kA
-cyc
ms
Breaker 2 operating time phase A
ms
Breaker 2 operating time phase B
ms
Breaker 2 operating time phase C
ms
Breaker 2 operating time
Breaker 3 arcing amp phase A
2
kA
-cyc
2
Breaker 3 arcing amp phase B
kA
-cyc