Error Codes

When you turn on the fixture, it will complete a start-up procedure.
Example:
means there is an error in channel 1. When multiple errors are present they will cycle
on the display twice, then the fixture will generate a second reset. Any errors that
remain after two reset cycles are not correctable by reset alone and will require ser-
vice. Please contact support if detailed assistance is needed.
Pan movement
This message displays after the reset of the fixture if any of the following conditions exist:
if the yoke's magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Pan movement is not located in the default position after the reset
l
Tilt movement
This message displays after the reset of the fixture if any of the following conditions exist:
if the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Tilt movement is not located in the default position after the reset
l
Color1
This message displays after the reset of the fixture if any of the following conditions exist:
if the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Color wheel movement is not located in the default position after the reset
l
Cyan, Magenta, or Yellow Color
This message displays after the reset of the fixture if any of the following conditions exist:
if the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the CMY movement is not located in the default position after the reset
l
CTO Color
This message displays after the reset of the fixture if any of the following conditions exist:
if the fixture head's magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the CTO movement is not located in the default position after the reset
l
For example, when the display shows "Err Info: Pan Movement", it