Error Messages - High End Systems SolaHyBeam 2000 User Manual

Table of Contents

Advertisement

ERROR MESSAGES

When you turn on the device, it will first perform a reset. The display may show "Err channel is XX" should
there be problems with one or more functions. "XX" stands for channel 1, 2, 3, 4, 5, 6, etc. whose sensor
has encountered a problem. For example, when the display shows "Err channel is Pan movement", it
means there is an error on channel 1. If there are errors on channel 1, channel 3, channel 9 at the same
time, you may see the error message, "Err channel is Pan movement", "Err channel is Tilt movement"" "Err
channel is CTO" ,flash twice, and then the device will generate a second reset. If the error messages
persist after performing a reset more than twice, the channels which have errors may not work properly
however, all other functions can work as usual. Please contact your dealer or manufacturer for service.
Self-repair is not allowed.
PAN- movement Er
(PAN- yoke movement error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (Optical Sensor or Magnetic Sensor fails) or the stepper motor is
defective (or it's driving IC on the main PCB). The PAN- movement is not located in the default position
after the reset.
TILT- movement Er
(TILT- head movement error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions ((Optical Sensor or Magnetic Sensor fails)) or the stepper motor is
defective (or it's driving IC on the main PCB). The TILT- movement is not located in the default position after
the reset.
CMY wheel Er
(CMY wheel- error) This message will appear after the reset of the fixture if the head's magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it's driving IC on
the main PCB). The CMY - movement is not located in the default position after the reset.
CTO wheel Er
(CTO wheel- error) This message will appear after the reset of the fixture if the head's magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it's driving IC on
the main PCB). The CTO - movement is not located in the default position after the reset.
COLOR wheel Er
(COLOR wheel- error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or it's driving IC on the main PCB). The COLOR - movement is not located in the default position after the
reset.
GOBO wheel Er
(GOBO wheel- error) This message will appear after the reset of the fixture if the head's magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it's driving IC on
the main PCB). The GOBO1 - movement is not located in the default position after the reset.
Frost 1 wheel Er
(Frost 1 wheel- error) This message will appear after the reset of the fixture if the head's magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it's driving IC on
the main PCB). The Frost1 - movement is not located in the default position after the reset.
Frost 2 wheel Er
(Frost 2 wheel- error) This message will appear after the reset of the fixture if the head's magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it's driving IC on
the main PCB). The Frost2 - movement is not located in the default position after the reset.
40
SolaHyBeam 2000 User Manual
v1.3

Advertisement

Table of Contents
loading