Service Pin; Rdm Uid; Ethernet Ip - High End Systems SolarFrame 750 User Manual

Professional moving head
Table of Contents

Advertisement

Set Universe
1. Press the [MODE/ESC] button to display the main menu.
2. Tap the [Up] or [Down] button until the "Set" option displays, then press [Enter]. The "Set" menu displays.
3. Tap the [Up] or [Down] button until the "Select Universe" option displays, then press [Enter]. The "Select
Input" menu displays.
4. Press [Up] or [Down] to modify the selection (000 - 255).
5. Press [Enter] to commit to the change or press the [MODE/ESC] button to return to the previous menu.
Service Setting
The settings in the "Service Setting" menu are password protected. You must enter the Service PIN first, then
additional menu settings will be accessible.

Service PIN

The Service PIN is "050".
RDM UID
Remote Device Management, or RDM, requires that all RDM devices have a unique identifier (UID) that consists
of the manufacturer ID and serial number. Modifying this setting can break the RDM capability of this fixture.
There cannot be duplicate RDM UID on the same DMX control run as this will result in a data collision, causing a
communication failure. Ensure that all fixtures have a unique RDM UID if RDM functionality is to be used.
Note:
If DMX splitters are used and RDM control is to be used, these splitters must sup-
port RDM.
1. Press the [MODE/ESC] button to display the main menu.
2. Tap the [Up] or [Down] button until the "Set" option displays, then press [Enter]. The "Set" menu displays.
3. Tap the [Up] or [Down] button until the "Service Setting" option displays, then press [Enter]. The "Service
Setting" menu displays.
4. Press the [Up] or [Down] button until "RDM UID" displays, then press [Enter]. If the Service PIN has not
been correctly applied in the previous menu, this menu will not be accessible. With successful Service
PIN entered, the current settings, manufacturer ID and fixture serial number, displays.
5. Press [Up] or [Down] to modify the fixture serial number to another setting. Do not duplicate RDM UID's in
a system as this will prevent the system from responding to RDM commands.
6. Press [Enter] to commit to the change or press the [MODE/ESC] button to return to the previous menu.

Ethernet IP

1. Press the [MODE/ESC] button to display the main menu.
2. Tap the [Up] or [Down] button until the "Set" option displays, then press [Enter]. The "Set" menu displays.
3. Tap the [Up] or [Down] button until the "Service Setting" option displays, then press [Enter]. The "Service
Setting" menu displays.
4. Press the [Up] or [Down] button until "Ethernet IP" displays, then press [Enter]. If the Service PIN has not
been correctly applied in the previous menu, this menu will not be accessible. With successful Service
PIN entered, the current IP settings will display. The default IP address is 002-142.058.034 with the last
octet (034) selected for edit.
5. Use the [Left] or [Right] buttons to change the octet selected, and press the [Up] or [Down] button to
31