Gobo1
This message displays after the reset of the fixture if any of the following conditions exist:
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if Gobo Wheel 1 is not located in the default position after the reset
l
Gobo1Rot
This message displays after the reset of the fixture if any of the following conditions exist:
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if Gobo Rotating Wheel 1 is not located in the default position after the reset
l
Focus
This message displays after the reset of the fixture if any of the following conditions exist:
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Focus movement is not located in the default position after the reset
l
Zoom
This message displays after the reset of the fixture if any of the following conditions exist:
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Zoom movement is not located in the default position after the reset
l
Frost
This message displays after the reset of the fixture if any of the following conditions exist:
if the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
l
if the stepper motor is defective or the related IC driver on the main PCB has failed
l
if the Frost movement is not located in the default position after the reset
l
45
Need help?
Do you have a question about the SolarFrame 750 and is the answer not in the manual?