Dmx Control Protocol; Error Codes - High End Systems SolaFrame Theatre User Manual

Table of Contents

Advertisement

DMX Control Protocol

The most current DMX Control Protocol data for the SolaFrame Theatre can be found on the High End
Systems, Inc. website:
https://www.highend.com/documentation/SolaFrame%20Theatre/SolaFrameTheatre-protocol.pdf

Error codes

When you turn on the fixture, the startup routine will check all functions. The display may show the "Err
channel is XX" message if there are problems found in one or more channels. "XX" stands for channel 1,
2, 3, 4, 5, 6 who has the testing sensor for positioning. For example, when the display shows "Err channel
is Pan Movement", it means there is some error in channel 1. If there multiple errors found, for example
on channel 1, channel 3, channel 11, you may see the error message, "Err channel is Pan movement",
"Err channel is Tilt movement" , "Err channel is Shutter", flash repeated for 2 times, and then the fixture
will attempt a homing routine. If the fixture error message remains after performing reset more than 2
times, only the channels which have errors will not work properly, others may work as usual. Please
contact with dealer or manufacturer for service.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke's
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is
defective (or it's driving IC on the main PCB). The PAN- movement is not located in the default
position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head's
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is
defective (or it's driving IC on the main PCB). The TILT- movement is not located in the default
position after the reset.
Color Wheel Er
(Color Wheel - error) This message will appear after the reset of the fixture if the magnetic-indexing
circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or it's driving
IC on the main PCB). The Color Wheel is not located in the default position after the reset.
SolaFrame Theatre v1.2.5
47
User Manual