Twisted-Pair Straight-Through Cable
To connect PCs or other MDI network devices to these ports, use a straight-
through cable.
brown
white/brown
orange
white/blue
blue
white/orange
green
white/green

Figure 16. Twisted-Pair Straight-Through Cable

Twisted-Pair Crossover Cable
To connect hubs or switches or other MDI-X network devices to these ports, use a
crossover cable.
brown
white/brown
orange
white/blue
blue
white/orange
green
white/green

Figure 17. Twisted-Pair Crossover Cable

CrossFire 8720 Fast Ethernet Layer 3 Switch, v. 1.00.02, P/N: 710001800
Pin
Pin
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
Pin
Pin
8
7
6
5
4
3
2
1
brown
white/brown
orange
white/blue
blue
white/orange
green
white/green
brown
8
white/brown
7
orange
6
white/blue
5
blue
4
white/orange
3
green
2
white/green
1
Straight Through Cable
(for connecting node to switch)
All conductors are wired to the same
RJ-45 connector pins on each end of
the cable. All color pairs (such as
white/blue and white/orange) are kept
twisted together (1,2; 3,6; 4,5; 7,8).
Crossover Cable
(for connecting switch to switch or
transceiver to transceiver)
Pairs 2 (pins 1 and 2) and
pair 3 (pins 3 and 6) are
crossed (note the different
color assignement at each
connector). All color pairs
are kept twisted together
(1,2; 3,6; 4,5; 7,8).