IE-SW-VL08M Series User's Manual
Relay Warning Events Settings
NOTE: The user interface for the IE-SW-VL08M shows 8 ports.
Event Types
Event Types can be divided into two basic groups: System Events and Port Events. System Events
are related to the overall function of the switch, whereas Port Events are related to the activity of a
specific port.
The switch supports one relay output. You can configure which relay output is related to which
events. This helps administrators identify the importance of the different events.
Power Transition (On Off)
Power Transition (Off On)
Turbo Ring Break (Ring Master
Only)
NOTE
If the Turbo Ring Switch function is enabled, and the Turbo Ring DIP Switch is set to "ON", the
Turbo Ring Break Event cannot be changed. If not, the Turbo Ring Break Event can be set by using
a web browser.
NOTE
The Turbo Ring Break Warning will be automatically enabled when the following configuration is
set:
1. Turbo Ring DIP Switch functions are enabled.
2. The Hardware Turbo Ring DIP Switch is set to "ON".
System Event
Warning Relay output is triggered when...
The device is powered up.
The device is powered down.
When the IE-SW-VL08M is the Master of this
Turbo Ring, and the Turbo Ring is disconnected.
3-64
Featured Functions