IE-SW-VL08M Series User's Manual
0x3502
0x3600
0x3601
0x3602
0x3603
0x3680
0x3681
0x3682
1 word
1 word
1 word
1 word
1 word
1 word
1 word
1 word
TR2 Coupling Port Backup status
(Only using in Dual Homing)
0x0000:Port Disabled
0x0001:Not Coupling Port
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Not Enable
TR2 Ring 1 status
0x0000:Healthy
0x0001:Break
0xFFFF:Turbo Ring V2 Not Enable
TR2 Ring 1 Master/Slave
0x0000:Slave
0x0001:Master
0xFFFF:Turbo Ring V2 Ring 1 Not Enable
TR2 Ring 1 1st Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 1 Not Enable
TR2 Ring 1 2nd Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 1 Not Enable
TR2 Ring 2 status
0x0000:Healthy
0x0001:Break
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
TR2 Ring 2 Master/Slave
0x0000:Slave
0x0001:Master
0xFFFF:Turbo Ring V2 Ring 2 Not Enable
TR2 Ring 2 1st Port status
0x0000:Port Disabled
0x0001:Not Redundant
0x0002:Link Down
0x0003:Blocked
0x0004:Learning
0x0005:Forwarding
0xFFFF:Turbo Ring V2 Ring 2 Not Enable