Any host can access the IE-SW-VL08M
Disable this function by not selecting the Enable the accessible IP list checkbox.
The following table shows additional configuration examples:
Allowable Hosts
Any host
192.168.1.120
192.168.1.1 to 192.168.1.254
192.168.0.1 to 192.168.255.254
192.168.1.1 to 192.168.1.126
192.168.1.129 to 192.168.1.254

Port

Port settings are included to give the user control over Port Access, Port Transmission Speed, Flow
Control, and Port Type (MDI or MDIX). An explanation of each configuration item is given below.
(NOTE: The user interface for the IE-SW-VL08M will show 8 ports.)
Enable
Setting
checked
unchecked
ATTENTION
If a connected device or sub-network is wreaking havoc on the rest of the network, the Disable
option under Advanced Settings/Port gives the administrator a quick way to immediately shut off
access through this port.
Description
Allows data transmission through the port.
Immediately shuts off port access.
3-4
Input format
Disable
192.168.1.120 / 255.255.255.255
192.168.1.0 / 255.255.255.0
192.168.0.0 / 255.255.0.0
192.168.1.0 / 255.255.255.128
192.168.1.128 / 255.255.255.128
Featured Functions
Factory Default
disabled