8.10 Tolerance weighing

For tolerance weighing compare the current weight value to a lower and upper limit.
These limits must have been stored beforehand.
When placing for instance ready-made packaging, it will be shown whether the
weight is within the allowable tolerance.
Operation:
Turn on display unit by pressing the ON/OFF key
Press F -key
Repeatedly press the a key until 3 HiLo appears
Press TARE key
To enter the lower tolerance limit (e. g. 90.00 g): Use the
TARE key, to select the digit to be changed, the a key
is used to increase the numerical value (active digit
flashing)
Press the PRINT key; the lower tolerance limit will be
imported.
To enter the upper tolerance limit (e. g. 110.00 g): Use the
TARE key, to select the digit to be changed, the a key
is used to increase the numerical value (active digit
flashing)
Press the PRINT key; the upper tolerance limit will be
imported and jumps to tolerance weighing mode.
Example for application: Weight:
Go back to weighing mode by pressing the F key twice.
The value entered for the upper tolerance limit must be greater than the lower
tolerance value. Error message –Lo- appears on the display and the display of the
unit returns to weighing mode.
34
50 g on weighing plate
Weight: 100g on weighing plate
Weight: 150g on weighing plate
Display:
0.00 g
1 Funi
3 HiLo
Min
0000.00g
Min
0090.00g
Max
0100.00g
Min
50.00g
Ok
100.00g
Max
150.00g
0.00 g