CHAPTER 3: INTERFACES

Offline Settings File Conversion

Convert SR 750/760
Files
850 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL
The EnerVista 8 Series Setup software supports conversion of offline settings files created
in the SR Series platform. The feature allows users, who have SR devices, to convert their
existing 750 offline settings files to 8 Series files and write them to their 850 devices.
The EnerVista 8 Series Setup software reduces the manual effort required when moving
from an older product to the 850. The feature takes an existing 750 settings file provided
by the user and generates a new settings file compatible with the 8 Series order code
specified by the user. After the import is complete, the results are displayed in an
interactive results window.
EnerVista 8 Series Setup software version supports conversion of SR 750/760 files to
850 settings files.
The conversion can only be initialized with EnerVista from the Offline/New Settings File
commands located in the taskbar.
1.
In the menu taskbar, click on Offline and select the New Settings File item. The
following Create New Setting s File dialog box appears, which allows for the setpoint
file conversion.
2.
Select the Firmware Version and Order Code option for the new setpoint file.
3.
For future reference, enter some useful information in the Description box to facilitate
the identification of the device and purpose for the file.
4.
To select the file name and path for the new file, click the button beside the File Name
box.
SOFTWARE INTERFACE