Dell PowerConnect 7000 Series Reference Manual page 1461

Systems cli reference guide
Hide thumbs Also See for PowerConnect 7000 Series:
Table of Contents

Advertisement

Parameter
startup direction
owner string
Default Configuration
No alarms are configured.
Command Mode
Global Configuration mode
User Guidelines
This command has no user guidelines.
Example
The following example configures the following alarm conditions:
Alarm index — 1
Variable identifier — 1.3.6.1.2.1.2.2.1.10.5
Sample interval — 10 seconds
Rising threshold — 500000
Falling threshold — 10
Rising threshold event index — 1
Falling threshold event index — 1
console(config)#rmon alarm 1 1.3.6.1.2.1.2.2.1.1.10.5 10
50000 10 1 1
Description
The alarm that may be sent when this entry is first set to valid.
If the first sample (after this entry becomes valid) is greater
than or equal to the rising-threshold, and direction is equal to
rising or rising-falling, then a single rising alarm is generated. If
the first sample (after this entry becomes valid) is less than or
equal to the falling-threshold, and direction is equal to falling
or rising-falling, then a single falling alarm is generated.
Enter a name that specifies who configured this alarm. If
unspecified, the name is an empty string.