<cr> Press enter to execute the command.
console(config-stack)#initiate failover
Management unit will be reloaded.
Are you sure you want to failover to the backup unit?
(y/n) y

locate

Use the locate command to locate a switch by LED blinking.
Syntax
locate [switch
Parameter Description
Parameter
unit
switch
time
time
Default Configuration
Default value is 20 seconds.
Command Mode
Privileged EXEC
User Guidelines
The LED will blink green until it times out. The user may select a new time
value while the LED is blinking. The last value selected takes effect
immediately. The locate command does not persist across reboots.
Example
console# locate switch 1 time 555
1588
System Management Commands
unit ] [time time ]
Description
If multiple devices are stacked, you can choose which
switch to identify.
LED blinking duration in seconds. Range 1-3600 seconds.