6. Troubleshooting
SC573-01
SC573-02
612
D
Temperature/Humidity Sensor – Temperature Error
The temperature/humidity sensor registered a temperature that was out of
range.
• Connection loose, broken, defective at CN217
• After correcting the problem, cycle the machine off/on
• Sensor defective
D
Temperature/Humidity Sensor Error (Humidity)
The temperature/humidity sensor registered a humidity reading that was out
of range.
• Connection loose, broken, defective at CN217
• After correcting the problem, cycle the machine off/on
• Sensor defective