CERT: Up State
Displays the status of the certification update.
0
The certification used by Embedded RC Gate is set correctly.
The certification request (setAuthKey) for update has been received from the GW
1
URL and certification is presently being updated.
The certification update is completed and the GW URL is being notified of the
2
successful update.
The certification update failed, and the GW URL is being notified of the failed
3
update.
The period of the certification has expired and new request for an update is
4
being sent to the GW URL.
A rescue update for certification has been issued and a rescue certification setting
11
is in progress for the rescue GW connection.
The rescue certification setting is completed and the GW URL is being notified of
12
67
the certification update request.
The notification of the request for certification update has completed successfully,
13
and the system is waiting for the certification update request from the rescue GW
URL.
The notification of the certification request has been received from the rescue GW
14
controller, and the certification is being stored.
The certification has been stored, and the GW URL is being notified of the
15
successful completion of this event.
The storing of the certification has failed, and the GW URL is being notified of the
16
failure of this event.
The certification update request has been received from the GW URL, the GW
URL was notified of the results of the update after it was completed, but a
17
certification error has been received, and the rescue certification is being
recorded.
The rescue certification of No. 17 has been recorded, and the GW URL is being
18
notified of the failure of the certification update.