Ricoh D124-17 Service Manual page 791

Table of Contents

Advertisement

2910
Maintenance Mode Setting DFU
1 to 30 Setting 1 to 30
2959
Engine Control IC ID Indication
This SP displays the name and firmware version number of the engine control module
(CHOPIN).
• The CHOPIN module on the IPU is initialized at power on.
• This controls the timing of the electrical system of the machine.
1 IC Name
Example: CHOP (CHOPIN)
[0 to 155/0/1]
2 Version
Example: 2400Dh
[0 to 0xFFFFFFFF/0/1]
2972
Forced Soft Count ON Threshold - t2 DFU`
This SP sets the threshold value to trigger forced software count. This count is done for
the OCFS software count for ink consumption and OCFS ink supply filling
[0 to 5/0.6/0.05 sec]
2973
OCFS Position Check DFU
If the temperature/humidity sensor inside the machine measures a significant change in
the humidity, this could affect the operation of the machine.
• A humidification correction value has been devised to alter the "full position" of the
OCFS feeler to compensate for adverse temperature and humidity.
• Normally, the sub tank feeler points straight forward when the tank is full.
However, the machine can automatically shift the full position automatically to
compensate for adverse temperature/humidity.
• The machine adjusts the position and the sensor "learns" the new full position.
These SP codes adjust this procedure.
1 OCFS Position Check Repeat -Humidity Fluctuation
SP2000
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mo-c1D124-21D124-27

Table of Contents