AudioCodes Mediant 800B User Manual page 785

Analog & digital voip media gateway
Hide thumbs Also See for Mediant 800B:
Table of Contents

Advertisement

User's Manual
Parameter
EMS: HTTPS Port
CLI: http-port
[HTTPport]
EMS: Disable WEB Config
[DisableWebConfig]
[ResetWebPassword]
Version 6.8
card and the device's Web interface, and a RADIUS server is
implemented to authenticate the password with the username.
Thus, this feature implements a two-factor authentication - what
the user has (the physical card) and what the user knows (i.e.,
the login password).
Defines the LAN HTTP port for Web management (default is
80). To enable Web management from the LAN, configure the
desired port.
Note: For this parameter to take effect, a device reset is
required.
Determines whether the entire Web interface is read-only.
[0] = (Default) Enables modifications of parameters.
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified. In
addition, the following pages can't be accessed: 'Web User
Accounts', 'Certificates', 'Regional Settings', 'Maintenance
Actions' and all file-loading pages ('Load Auxiliary Files',
'Software Upgrade Wizard', and 'Configuration File').
Note: For this parameter to take effect, a device reset is
required.
Resets the username and password of the primary ("Admin")
and secondary ("User") accounts to their default settings
("Admin" and "Admin" respectively), and deletes all other users
that may have been configured.
[0] = (Default) Password and username retain their values.
[1] = Password and username are reset.
Notes:
For this parameter to take effect, a device reset is required.
You cannot reset the username and password through the
Web interface (by loading an ini file or on the AdminPage).
To reset the username and password:
SNMP:
1) Set acSysGenericINILine to
WEBPasswordControlViaSNMP = 1, and reset the
device with a flash burn (set
acSysActionSetResetControl to 1 and
acSysActionSetReset to 1).
2) Change the username and password in the
acSysWEBAccessEntry table. Use the following format:
Username acSysWEBAccessUserName: old/pass/new
Password acSysWEBAccessUserCode:
username/old/new
785
57. Configuration Parameters Reference
Description
Mediant 800B Gateway and E-SBC

Advertisement

Table of Contents
loading

Table of Contents