Task navigation
You can activate the checkbox in column "Set to 1" to forcely set the signal status to 1.
For the signal EMGS, it can be forcely set to 1 when the drive firmware version is
V1.04.00 and higher.
Note
Signal P_TRG in PTI mode is reserved for future use.
4.3.6.2

Assigning digital outputs

You can assign digital outputs on the following panels:
● Assigning digital outputs for V90 PN
A total of seven signals can be freely linked to digital outputs. For more information, see
Section "DOs (Page 95)".
Click the cells with white background in the table. Select "Assign" to link the digital input
with the corresponding signal. Then the current cell displays grey.
DO signal reverse
You can reverse the logics of DO1 and DO2 by activating the checkboxes in the following
function area or setting the bit 0 and bit 1 of parameter p748:
After the DO port is reversed, an "/" appears before the DO port to indicate that the logic
of the signal assigned to this port has been reversed.
76
SINAMICS V-ASSISTANT Online Help
Operating Manual, 04/2017, A5E36618042-003