setpoint is activated by a PRBS signal. The evaluation of the signals is performed in the
frequency range.
● Current controller setpoint frequency response(after current setpoint filter)
For the reference frequency response on the current controller, the current setpoint is
activated by a PRBS signal. The evaluation of the signals is performed in the frequency
range.
Note
Measuring machine is only available in online mode.
Overview
Area
Item
Measuring functions
Amplitude
128
Description
Speed controller setpoint frequency response(before speed setpoint filter)
Speed control system(excitation after current setpoint filter)
Current controller setpoint frequency response(after current setpoint filter)
The value of the signal amplitude to be applied
For the current controller, the specification is a relative value in percent. The
value refers to the reference current (p2002). For the speed controller, the ampli-
tude specification is always in physical units.
SINAMICS V-ASSISTANT Online Help
Operating Manual, 04/2017, A5E36618042-003