Task navigation
Error values
See the table below for error values in the parameter response.
Error
Meaning
value 1
00 hex
Illegal parameter number (access to a parameter that does not exist)
01 hex
Parameter value cannot be changed (change request for a parameter value that cannot be changed)
02 hex
Lower or upper value limit exceeded (change request with a value outside the value limits)
03 hex
Incorrect subindex (access to a parameter index that does not exist)
04 hex
No array (access with a subindex to non-indexed parameters)
05 hex
Incorrect data type (change request with a value that does not match the data type of the parameter)
06 hex
Setting not permitted, only resetting (change request with a value not equal to 0 without permission)
07 hex
Descriptive element cannot be changed (change request to a descriptive element that cannot be changed)
09 hex
Description data not available (access to a description that does not exist, parameter value is available)
0B hex
No master control (change request but with no master control)
0F hex
Text array does not exist (although the parameter value is available, the request is made to a text array that
does not exist)
11 hex
Request cannot be executed due to the operating state (access is not possible for temporary reasons that are
not specified)
14 hex
Inadmissible value (change request with a value that is within the limits but which is illegal for other permanent
reasons, i.e. a parameter with defined individual values)
15 hex
Response too long (the length of the actual response exceeds the maximum transfer length)
16 hex
Illegal parameter address (illegal or unsupported value for attribute, number of elements, parameter number,
subindex or a combination of these)
17 hex
Illegal format (change request for an illegal or unsupported format)
18 hex
Number of values not consistent (number of values of the parameter data to not match the number of elements
in the parameter address)
19 hex
Drive object does not exist (access to a drive object that does not exist)
20 hex
Parameter text cannot be changed
21 hex
Service is not supported (illegal or not support request ID).
6B hex
A change request for a controller that has been enabled is not possible. (The drive rejects the change request
because the motor is switched on. Please observe the "Can be changed" parameter attribute (U, T) as given in
the parameter list relevant section in the SINAMICS V90, SIMOTICS S-1FL6 Operating Instructions.
6C hex
Unknown unit.
77 hex
Change request is not possible during download.
81 hex
Change request is not possible during download.
82 hex
Accepting the master control is inhibited.
83 hex
Desired interconnection is not possible (the connector output does not supply a float value although the con-
nector input requires a float value)
84 hex
Inverter does not accept a change request(inverter is busy with internal calculations.
85 hex
No access methods defined.
87 hex
Know-how protection active, access locked
C8 hex
Change request below the currently valid limit (change request to a value that lies within the "absolute" limits,
but is however below the currently valid lower limit)
150
SINAMICS V-ASSISTANT Online Help
Operating Manual, 04/2017, A5E36618042-003