Digital Inputs/Outputs (Dis/Dos) - Siemens Sinamics V90 Operating Instructions Manual

Pulse train, uss/modbus interface
Hide thumbs Also See for Sinamics V90:
Table of Contents

Advertisement

Connecting
4.3 Control/status interface - X8
4.3.1

Digital inputs/outputs (DIs/DOs)

SINAMICS V90 supports free assignment of signals to the following digital input and output
terminals depending on the control mode selected:
DI1 to DI8 -- Assignable with parameters p29301 to p29308
DO1 to DO6 -- Assignable with parameters p29330 to p29335
Exception: DI9 and DI10
DI9 is permanently assigned with the signal EMGS (quick stop) and DI10 is permanently
assigned with the signal C-MODE (change mode).
For detailed information about default DI/DO signal assignments, see the table below:
Pin No.
Digital in-
puts/outputs
5
DI1
6
DI2
7
DI3
8
DI4
9
DI5
10
DI6
11
DI7
12
DI8
30
DO1
31
DO2
32
DO3
29/33
DO4
34/44
DO5
35/49
DO6
Note
The selected DI signal will respond with a delay time of 8 ms to 16 ms.
Note
DO signal inverse
The logics of digital output signals DO1 to DO6 can be inversed. You can inverse the logics
of DO1 to DO6 by setting the bit 0 to bit 5 of parameter p0748.
122
Parameters
Index 0 (PTI)
p29301
1 (SON)
p29302
2 (RESET)
p29303
3 (CWL)
p29304
4 (CCWL)
p29305
5 (G-
CHANGE)
p29306
6 (P-TRG)
p29307
7 (CLR)
p29308
10 (TLIM1)
p29330
p29331
p29332
p29333
p29334
p29335
Default signals/values
Index 1 (IPos)
Index 2 (S)
1 (SON)
1 (SON)
2 (RESET)
2 (RESET)
3 (CWL)
3 (CWL)
4 (CCWL)
4 (CCWL)
5 (G-
12 (CWE)
CHANGE)
6 (P-TRG)
13 (CCWE)
21 (POS1)
15 (SPD1)
22 (POS2)
16 (SPD2)
1 (RDY)
2 (FAULT)
3 (INP)
5 (SPDR)
6 (TLR)
8 (MBR)
Operating Instructions, 04/2019, A5E36037884-007
Index 3 (T)
Index 9
(Fast PTI)
1 (SON)
1 (SON)
2 (RESET)
2 (RESET)
3 (CWL)
8
(EGEAR1)
4 (CCWL)
9
(EGEAR2)
12 (CWE)
5 (G-
CHANGE)
13 (CCWE)
19 (SLIM1)
18 (TSET)
7 (CLR)
19 (SLIM1)
10 (TLM1)
SINAMICS V90, SIMOTICS S-1FL6