Weighing; Nominal Load - Miele PW 811 Operating And Installation Instructions

Table of Contents

Advertisement

Programming

Weighing

Nominal load

130
Create
 Program header
Area 1
:
1
Block
Area 2
: No
Tip: Selection and input of Name Area 1 is the same as for program
names.
Input for Areas 2 and 3 is identical to Area 1.
Configuration of the way in which the laundry load weight should be
established.
Use the multifunction selector to select "Weigh" and press to con-
firm the selection.
Create
 Program header
Weighing
:
:
No
Max. load
:
11,0 kg
You have the following options:
– No
The controls assume that nominal load is always assured. Manual
weight input before start of program is not possible.
– Manual
Laundry weight can be entered by hand before the program start.
– Automatic
Laundry weight is measured automatically in the machine.
A laundry weight can be allocated to a program with this option.
Turn the multifunction selector to "Nominal load" and press to con-
firm the selection.
Maximum nominal load value is dependent on the model and is as
follows:
for PW 811 - 24 lb / 11 kg
for PW 814 - 30 lb /14 kg
for PW 818 - 40 lb /18 kg
You have the following options:
– From 0.0 lb / kg, in 1/2 lb / 0.2 kg - increments to maximum nomi-
nal load.
Set a laundry weight.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pw 814Pw 818