Weighing Sytem; Suds Tap Connection - Miele PW 6163 Operating Instructions Manual

Table of Contents

Advertisement

Optional modules

Weighing sytem

If the machine has been equipped with a
weighing system module the weight of the
laundry in the machine will be displayed in
0.2 kg increments. The maximum load for
the programme selected will show next to
the actual weight in the drum.
Please make sure that there is nothing on
or leaning against the machine as these
will be weighed with the laundry.
If when the drum is empty the load display is
not showing "00,0", you will need to press
the -> I <- "button to set it to 0".
7
Cottons
60 °C
Main wash
Rinses
m
k
+i
If after calibrating the sensor to 0 there was
still laundry in the drum the following will
appear in the display:
7
Cottons
60 °C
Main wash
Rinses
m
k
+i
Press the -> I <- button again to set it to 0.
If there is too much laundry in the drum, e.g.
because it is wet, a nominal load will be
calculated after starting the programme and
this value will also be saved by the operating
data module.
At the end of the programme when the drum
has stopped rotating the display will show
the residual moisture content of the laundry.
7
Cottons
Programme finished
The door can be opened.
m
32
00,0/ 16.0 kg
e
A
m
-> I <-
-,- /
16.0 kg
e
A
m
-> I <-
Residual moisture 60 %
FC
A

Suds tap connection

For analysing suds in the required
programme stage.
^ Unscrew the suds tap connection cap on
the door with a suitable screwdriver.
^ Guide the hose through the opening (C13
mm).
^ Connect a syringe or pipette to the hose
and extract a sample of suds.
^ Screw the cap back in.