4. Heating
5. Free tempera-
ture selection
6. Temperature
7. Hysteresis
8. Warm Up
– Yes
The output "Program stop" is activated for a program stop.
Used to allow suppression of the heating.
Tip: This function can be used e.g. for warm rinses.
Choose from the following options:
– Yes
The heating is activated normally in the heating regulation circuit to
reach the required temperature.
– No
The heating is not switched on. The selected temperature should be
achieved exclusively via the water valve control. With the Thermostop
setting only "No" is possible. The field in the display for the target
temperature remains empty before and after the program start.
Used to make changes to temperature before program start.
Choose from the following options:
– No
Always heated to the temperature set in the block programming.
– Yes
The temperature of the 1st main wash set before program start is car-
ried over to all programed blocks, but only if "Yes" is programmed in
those blocks in the "Free temperature selection" programm stage and
if the temperature programmed in the block is not lower.
Used to program a temperature.
Choose from the following options:
– cold
The heating is not activated.
– 59 to 2013 °F / 15 to 95 °C
With increments of 2 °F / 1 °C temperature values are freely program-
mable.
Temperature difference between heating switch-on-and switch-off
points.
Choose from the following options:
– Normal (Off 32 °F / 0 °C, On 21 °F / -6 °C)
– Low (Off 37 °F / +3 °C, On 32 °F / 0 °C)
– User defined
37 °F to 14 °F / +3 °C to –10 °C in 2 °F /1 °C increments
Heating up speed, how rapidly the water should heat up
Programming
137