Delete data
Operating data module
Programme data
Delete data
\
After selecting Delete data the following
message will appear in the display:
Operating data module~ Delete data
Module: 21.02.2004
Total data: 12.07.2004
\
The module menu option can be used to
delete the total data and programme data
from the operating data memory.
The total data option can only be used to
delete the total data from the operating data.
The programme data option can only be
used to delete programme data from the
operating data.
After making your selection and pressing the
rotary dial you will be prompted to enter your
password.
Password: _ _ _ _
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789
After keying in your password or inserting
your supervisor level key card in the reader
the following security prompt will appear in
the display:
Delete operating data?
After pressing the S button the data will be
deleted!
M.-Nr. 06 533 412
e
A
e
A
A
K
S
A
S

Weighing sytem

If the machine has been equipped with a
weighing system module the weight of the
laundry in the machine will be displayed in
0.2 kg increments. The maximum load for
the programme selected will show next to
the actual weight in the drum.
If when the drum is empty the load display is
not showing "00,0", you will need to press
the -> I <- " to reset it
1
Cottons
60 °C
Main wash
Rinses
m
k
+i
If after calibrating the sensor to 0 there was
still laundry in the drum the following will
appear in the display:
1
Cottons
60 °C
Main wash
Rinses
m
k
+i
Press the -> I <- button again to set it to 0.
If there is too much laundry in the drum, e.g.
because it is wet, a nominal load will be
calculated after starting the programme and
this value will also be saved by the operating
data module.
At the end of the programme when the drum
has stopped rotating the display will show
the residual moisture content of the laundry.
1
Cottons
Programme finished
The door can be opened.
m
Optional modules
00,0/ 16.0 kg
m
-> I <-
—,- / 16.0 kg
m
-> I <-
Residual moisture 60 %
FC
e
A
e
A
A
31