Read Virtual Digital Input Configuration; Read Single Virtual Digital Input Configuration; Read Single Virtual Digital Input Configuration - Reply Ok - gefran SBI-DN Instruction Manual

Interface board devicenet
Table of Contents

Advertisement

DATA TYPE
Byte
For error codes see chapter 6.0.
1)

5.1.6.2 Read Virtual Digital Input Configuration

In this example is shown the reading of the configuration of the "Virtual Digital Inputs";
the cases of positive and wrong reading are distinguished.

5.1.6.2.1 Read Single Virtual Digital Input Configuration

The data frame for the reading of the single configuration of the "Virtual Digital
Inputs" is composed as follows:
DATA TYPE
Byte
1)
See Note
Byte
Byte or Word depending on the type of allocation executed by the Master.
1)

5.1.6.2.2 Read Single Virtual Digital Input Configuration - Reply OK

If the single configuration of the "Virtual Digital Inputs" is read correctly, the response
is composed as follows:
DATA TYPE
Byte
Word
The format of the Drive parameter index is Low Byte - High byte.
1)
——————
SBI-DN
FIELD
VALUE
Service
14hex OR
Code
80hex
1Fhex
General
Error
<> 1Fhex
1)
Additional
XX
FIELD
VALUE
Service Code
0Ehex
Class ID
6Ahex
Instance ID
01
Attribute ID
XX
FIELD
VALUE
0Ehex OR
Service Code
80hex
Word 0 Virtual
XXXX
Digital Input
Interface Board DeviceNet
MEANING
Set _Attribute_Single Reply
code- Common Service.
Error vendor specific (see
Additional field)
DeviceNet specific error
code (see DeviceNet
Specifications).
Drive specific error code.
MEANING
Get_Attribute_Single - Common
Service.
Virtual Digital I/O
Configuration Class Object
Virtual Digital Input Instance
ID
Virtual Digital Input XX word
involved in the configuration
MEANING
Get_Attribute_Single Reply code-
Common Service.
Drive parameter index assigned to
1)
the Virtual Digital Input XX
word.
——————
dn4050
dn5050
dn5060
43

Advertisement

Table of Contents
loading