3.2.1.6.2.2 Read APC parameter - Reply OK

If the APC-parameter is read correctly, the response is:
DATA TYPE
Byte
Word
Byte
1)
For data-type codes see APC-manual.

3.2.1.6.2.3 Read APC parameter - Reply Error

If the reading of the APC-parameter is rejected, the response is the following:
DATA TYPE
Byte
Word
1) For error codes see APC-manual.
——————
SBI-DN
FIELD
VALUE
Service
32hex OR
Code
80hex
Result
0000
Data Type
XX
1)
N/U
00
XX
XX
VALUE
XX
XX
FIELD
VALUE
Service
32hex OR
Code
80hex
1)
Result
XXXX
Interface Board DeviceNet
MEANING
Get APC Parameter Reply
code- Object Specific
Service.
Result field equal to zero
means reading correctly
executed.
APC specific data type
code.
Not used; has to be set to
zero.
Low byte-Low word APC
parameter value.
High byte-Low word APC
parameter value.
Low byte-High word APC
parameter value.
High byte-High word APC
parameter value.
dn3985
MEANING
Get APC Parameter Reply
code- Object Specific
Service
APC specific error code
dn3990
——————
25