Read Single Polling S->M Configuration - Reply Ok; Read Single Polling S->M Configuration - Reply Error; Read Entire Polling S->M Configuration; Read Entire Polling S->M Configuration - Reply Ok - gefran SBI-DN Instruction Manual

Interface board devicenet
Table of Contents

Advertisement

4.1.6.2.2 Read Single Polling S->M Configuration - Reply OK
If the single configuration of the Polling S->M is read correctly, the response is
composed as follows:
DATA TYPE
Byte
Word
The format of the Drive parameter index is Low Byte - High byte.
1)
4.1.6.2.3 Read Single Polling S->M Configuration - Reply Error
If the reading of the single configuration of the Polling S->M is rejected, the response
is the following:
DATA TYPE
Byte
For error codes see chapter 6.0.
1)
4.1.6.2.4 Read Entire Polling S->M Configuration
The data frame for the reading of the entire configuration of the Polling S->M is
composed as follows:
DATA TYPE
Byte
1)
See Note
Byte or Word depending on the type of allocation executed by the Master.
1)
4.1.6.2.5 Read Entire Polling S->M Configuration - Reply OK
If the entire configuration of the Polling S->M is read correctly, the response is
composed as follows:
——————
SBI-DN
FIELD
VALUE
0Ehex OR
Service Code
80hex
Word XX
XXXX
Polling S->M
FIELD
VALUE
Service
14hex OR
Code
80hex
1Fhex
General
Error
<> 1Fhex
1)
Additional
XX
FIELD
VALUE
Service Code
01hex
Class ID
68hex
Instance ID
01
Interface Board DeviceNet
MEANING
Get_Attribute_Single Reply
code- Common Service.
Drive parameter index assigned
1)
to the Polling S->M XX word.
MEANING
Get _Attribute_Single Reply
code- Common Service.
Error vendor specific (see
Additional field)
DeviceNet specific error
code (see DeviceNet
Specifications).
Drive specific error code.
MEANING
Get_Attribute_All -Common
Service.
Polling S->M Configuration
Class Object.
Polling S->M Instance ID.
——————