Write Single Polling S->M Configuration - Reply Error; Write Entire Polling S->M Configuration - gefran SBI-DN Instruction Manual

Interface board devicenet
Table of Contents

Advertisement

DATA TYPE
Byte
4.1.6.1.3 Write Single Polling S->M Configuration - Reply Error
If the writing of the single configuration Polling S->M is rejected, the response is
the following:
DATA TYPE
Byte
1)
4.1.6.1.4 Write Entire Polling S->M Configuration
The data frame for the writing of the entire configuration of the Polling S->M is
composed as follows:
DATA TYPE
Byte
1)
See Note
Word
Byte or Word depending on the type of allocation executed by the Master.
1)
The format of the Drive parameter index is Low Byte - High byte.
2)
——————
SBI-DN
FIELD
VALUE
Service
10hex OR
Code
80hex
General
00
Error
Additional
00
FIELD
VALUE
Service
14hex OR
Code
80hex
1Fhex
General
Error
<> 1Fhex
1)
Additional
XX
For error codes see chapter 6.0.
FIELD
VALUE
Service Code
02hex
Class ID
68hex
Instance ID
01
Word 0 Polling
S->M
Word xx Polling
XXXX
S->M
Word 3 Polling
S->M
Interface Board DeviceNet
MEANING
Set_Single - Attribute Reply
code - Common Service.
Zero means service correctly
executed
MEANING
Set _Attribute_Single Reply
code- Common Service.
Error vendor specific (see
Additional field)
DeviceNet specific error
code (see DeviceNet
Specifications).
Drive specific error code.
MEANING
Set_Attribute_All -Common
Service.
Polling S->M Configuration
Class Object.
Polling S->M Instance ID.
Drive parameter index assigned
to the Polling S->M first word.
Drive parameter index assigned
2)
to the Polling S->M xx th word.
Drive parameter index assigned
to the Polling S->M 4th word.
——————
dn4040
dn4050
dn4060
29