4.1.6.1.5 Write Entire Polling S->M Configuration - Reply OK
If the entire configuration of the Polling S->M is written correctly, the response is
composed as follows:
DATA TYPE
Byte
4.1.6.1.6 Write Entire Polling S->M Configuration - Reply Error
If the writing of the entire configuration of the Polling S->M is rejected, the response
is the following:
DATA TYPE
Byte
For error codes see chapter 6.0
1)
4.1.6.2 Read S->M Polling Configuration
In this example is shown the reading of the configuration of the Polling S->M; the
cases of positive and wrong reading are distinguished.
4.1.6.2.1 Read Single Polling S->M Configuration
The data frame for the reading of the single configuration of the Polling S->M is
composed as follows:
DATA TYPE
Byte
See Note
Byte
Byte or Word depending on the type of allocation executed by the Master.
1)
30
——————
GEFRAN
FIELD
VALUE
Service
02hex OR
Code
80hex
General
00
Error
Additional
00
FIELD
VALUE
Service
14hex OR 80hex
Code
1Fhex
General
Error
<> 1Fhex
1)
Additional
XX
FIELD
VALUE
Service Code
0Ehex
Class ID
68hex
1)
Instance ID
Attribute ID
XX
Interface Board DeviceNet
MEANING
Set_Attribute_All Reply
code- Common Service.
Zero means service correctly
executed.
MEANING
Set _Attribute_ All Reply code-
Common Service
Error vendor specific (see
Additional field)
DeviceNet specific error code
(see DeviceNet Specifications)
Drive specific error code.
MEANING
Get_Attribute_Single -
Common Service
Polling S ->M Configuration
Class Object
01
Polling S ->M Instance ID
Polling S ->M word involved
in configuration
——————
dn4070
dn4080
dn4090