APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 41 of 59)
ADDR
REGISTER NAME
9913
...Repeated for IEC61850 GOOSE UInteger 2
9916
...Repeated for IEC61850 GOOSE UInteger 3
9919
...Repeated for IEC61850 GOOSE UInteger 4
991C
...Repeated for IEC61850 GOOSE UInteger 5
991F
...Repeated for IEC61850 GOOSE UInteger 6
9922
...Repeated for IEC61850 GOOSE UInteger 7
9925
...Repeated for IEC61850 GOOSE UInteger 8
9928
...Repeated for IEC61850 GOOSE UInteger 9
992B
...Repeated for IEC61850 GOOSE UInteger 10
992E
...Repeated for IEC61850 GOOSE UInteger 11
9931
...Repeated for IEC61850 GOOSE UInteger 12
9934
...Repeated for IEC61850 GOOSE UInteger 13
9937
...Repeated for IEC61850 GOOSE UInteger 14
993A
...Repeated for IEC61850 GOOSE UInteger 15
993D
...Repeated for IEC61850 GOOSE UInteger 16
FlexElement Actuals (Read Only) (16 modules)
9A01
FlexElement™ 1 Actual
9A03
FlexElement™ 2 Actual
9A05
FlexElement™ 3 Actual
9A07
FlexElement™ 4 Actual
9A09
FlexElement™ 5 Actual
9A0B
FlexElement™ 6 Actual
9A0D
FlexElement™ 7 Actual
9A0F
FlexElement™ 8 Actual
Breaker restrike (read/write settings)
9AD9
Breaker restrike 1 function
9ADA
Breaker restrike 1 block
9ADB
Breaker restrike 1 signal source
9ADC
Breaker restrike 1 pickup
9ADD
Breaker restrike 1 reset delay
9ADE
Breaker restrike 1 HF detect
9ADF
Breaker restrike 1 breaker open
9AE0
Breaker restrike 1 open command
9AE1
Breaker restrike 1 close command
9AE2
Breaker restrike 1 target
9AE3
Breaker restrike 1 events
9AE4
Reserved (2 items)
9AE6
...Repeated for breaker restrike 2
VT Fuse Failure (Read/Write Setting) (6 modules)
A09A
VT Fuse Failure Function
A09B
VT Fuse Failure Neutral Wire Open Function
A09C
VT Fuse Failure Neutral Wire Open 3rd Harmonic Pickup
A041
...Repeated for module number 2
A042
...Repeated for module number 3
A043
...Repeated for module number 4
A044
...Repeated for module number 5
A045
...Repeated for module number 6
Permissive overreach transfer trip (POTT) settings (read/write)
A070
POTT Scheme Function
A071
POTT Permissive Echo
A072
POTT Rx Pickup Delay
A073
POTT Transient Block Pickup Delay
A074
POTT Transient Block Reset Delay
A075
POTT Echo Duration
GE Multilin
RANGE
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
-2147483.647 to 2147483.647
0 to 1
0 to 65535
0 to 5
0.10 to 2.00
0 to 65.535
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 1
0 to 3
0 to 1
0 to 1
0 to 65.535
0 to 65.535
0 to 65.535
0 to 65.535
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
0.001
F004
---
1
F102
---
1
F300
---
1
F167
pu
0.01
F001
s
0.001
F001
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F102
pu
0.001
F001
---
1
F102
---
1
F102
s
0.001
F001
s
0.001
F001
s
0.001
F001
s
0.001
F001
DEFAULT
B
0
0
0
0
0
0
0
0
0 (Disabled)
0
0 (SRC 1)
500
100
1 (Enabled)
0
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (Disabled)
100
0 (Disabled)
0 (Disabled)
0
20
90
100
B-49