GE L90 Instruction Manual page 585

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 7 of 59)
ADDR
REGISTER NAME
Breaker flashover (read/write setting) (2 modules)
21A6
Breaker flashover 1 function
21A7
Breaker flashover 1 side 1 source
21A8
Breaker flashover 1 side 2 source
21A9
Breaker flashover 1 status closed A
21AA
Breaker flashover 1 status closed B
21AB
Breaker flashover 1 status closed C
21AC
Breaker flashover 1 voltage pickup level
21AD
Breaker flashover 1 voltage difference pickup level
21AF
Breaker flashover 1 current pickup level
21B0
Breaker flashover 1 pickup delay
21B1
Breaker flashover 1 supervision phase A
21B2
Breaker flashover 1 supervision phase B
21B3
Breaker flashover 1 supervision phase C
21B4
Breaker flashover 1 block
21B5
Breaker flashover 1 events
21B6
Breaker flashover 1 target
21B7
Reserved (4 items)
21BB
...Repeated for breaker flashover 2
Breaker Arcing Current Actuals (Read Only Non-Volatile) (2 modules)
21E0
Breaker 1 Arcing Current Phase A
21E2
Breaker 1 Arcing Current Phase B
21E4
Breaker 1 Arcing Current Phase C
21E6
Breaker 1 Operating Time Phase A
21E7
Breaker 1 Operating Time Phase B
21E8
Breaker 1 Operating Time Phase C
21E9
Breaker 1 Operating Time
21EA
...Repeated for Breaker Arcing Current 2
Breaker Arcing Current Commands (Read/Write Command) (2 modules)
2224
Breaker 1 Arcing Current Clear Command
2225
Breaker 2 Arcing Current Clear Command
Passwords Unauthorized Access (Read/Write Command)
2230
Reset Unauthorized Access
Fault Location (Read Only) (5 modules)
2340
Fault 1 Prefault Phase A Current Magnitude
2342
Fault 1 Prefault Phase A Current Angle
2343
Fault 1 Prefault Phase B Current Magnitude
2345
Fault 1 Prefault Phase B Current Angle
2346
Fault 1 Prefault Phase C Current Magnitude
2348
Fault 1 Prefault Phase C Current Angle
2349
Fault 1 Prefault Phase A Voltage Magnitude
234B
Fault 1 Prefault Phase A Voltage Angle
234C
Fault 1 Prefault Phase B Voltage Magnitude
234E
Fault 1 Prefault Phase B Voltage Angle
234F
Fault 1 Prefault Phase C Voltage Magnitude
2351
Fault 1 Prefault Phase C Voltage Angle
2352
Fault 1 Phase A Current Magnitude
2354
Fault 1 Phase A Current Angle
2355
Fault 1 Phase B Current Magnitude
2357
Fault 1 Phase B Current Angle
2358
Fault 1 Phase C Current Magnitude
235A
Fault 1 Phase C Current Angle
235B
Fault 1 Phase A Voltage Magnitude
235D
Fault 1 Phase A Voltage Angle
GE Multilin
RANGE
0 to 1
0 to 5
0 to 6
0 to 65535
0 to 65535
0 to 65535
0 to 1.5
0 to 100000
0 to 1.5
0 to 65.535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 2
---
0 to 99999999
0 to 99999999
0 to 99999999
0 to 99999999
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
0 to 999999.999
-359.9 to 0
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
---
1
F211
---
1
F300
---
1
F300
---
1
F300
pu
0.001
F001
V
1
F060
pu
0.001
F001
s
0.001
F001
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F102
---
1
F109
---
---
F001
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
2
kA
-cyc
1
F060
ms
1
F001
ms
1
F001
ms
1
F001
ms
1
F001
---
1
F126
---
1
F126
---
1
F126
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
A
0.001
F060
degrees
0.1
F002
V
0.001
F060
degrees
0.1
F002
DEFAULT
0 (Disabled)
0 (SRC 1)
0 (None)
0
B
0
0
850
1000
600
100
0
0
0
0
0 (Disabled)
0 (Self-Reset)
0
0
0
0
0
0
0
0
0
0 (No)
0 (No)
0 (No)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B-15