GE L90 Instruction Manual page 611

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 33 of 59)
ADDR
REGISTER NAME
7745
Repeated for Thermal Protection 2
Broken conductor detection (Read/Write Settings)
7752
Broken Conductor 1 Function
7753
Broken Conductor 1 Source
7754
Broken Conductor 1 I2/I1 Ratio
7755
Broken Conductor 1 I1 Minimum
7756
Broken Conductor 1 I1 Maximum
7757
Broken Conductor 1 Pickup Delay
7758
Broken Conductor 1 Block
7759
Broken Conductor 1 Target
775A
Broken Conductor 1 Events
775B
Reserved (2 items)
775D
...Repeated for Broken Conductor 2
Phasor Measurement Unit Power Trigger (Read/Write Setting)
7860
PMU 1 Power Trigger Function
7861
PMU 1 Power Trigger Active
7862
PMU 1 Power Trigger Reactive
7863
PMU 1 Power Trigger Apparent
7864
PMU 1 Power Trigger Pickup Time
7865
PMU 1 Power Trigger Dropout Time
7866
PMU 1 Power Trigger Block (3 items)
7869
PMU 1 Power Trigger Target
786A
PMU 1 Power Trigger Events
Phasor Measurement Unit Voltage Trigger (Read/Write Setting)
788C
PMU 1 Voltage Trigger Function
788D
PMU 1 Voltage Trigger Low Voltage
788E
PMU 1 Voltage Trigger High Voltage
788F
PMU 1 Voltage Trigger Pickup Time
7890
PMU 1 Voltage Trigger Dropout Time
7891
PMU 1 Voltage Trigger Block (3 items)
7894
PMU 1 Voltage Trigger Target
7895
PMU 1 Voltage Trigger Events
Phasor Measurement Unit One-shot Command (Read/Write Setting)
78B4
PMU One-shot Function
78B5
PMU One-shot Sequence Number
78B6
PMU One-shot Time
Phasor Measurement Unit Test Values (Read/Write Setting)
78B8
PMU 1 Test Function
78B9
PMU 1 Phase A Voltage Test Magnitude
78BB
PMU 1 Phase A Voltage Test Angle
78BC
PMU 1 Phase B Voltage Test Magnitude
78BE
PMU 1 Phase B Voltage Test Angle
78BF
PMU 1 Phase C Voltage Test Magnitude
78C1
PMU 1 Phase C Voltage Test Angle
78C2
PMU 1 Auxiliary Voltage Test Magnitude
78C4
PMU 1 Auxiliary Voltage Test Angle
78C5
PMU 1 Phase A Current Test Magnitude
78C7
PMU 1 Phase A Current Test Angle
78C8
PMU 1 Phase B Current Test Magnitude
78CA
PMU 1 Phase B Current Test Angle
78CB
PMU 1 Phase C Current Test Magnitude
78CD
PMU 1 Phase C Current Test Angle
78CE
PMU 1 Ground Current Test Magnitude
78D0
PMU 1 Ground Current Test Angle
GE Multilin
RANGE
0 to 1
0 to 5
20 to 100
0.05 to 1
0.05 to 5
0 to 65.535
0 to 65535
0 to 2
0 to 1
---
0 to 1
0.25 to 3
0.25 to 3
0.25 to 3
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0.25 to 1.25
0.75 to 1.75
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 99
0 to 235959
0 to 1
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 700
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
-180 to 180
0 to 9.999
-180 to 180
L90 Line Current Differential System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
%
0.1
F001
pu
0.01
F001
pu
0.01
F001
s
0.001
F001
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
pu
0.001
F001
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
pu
0.001
F001
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F001
---
1
F050
---
1
F102
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kV
0.01
F003
°
0.05
F002
kA
0.001
F004
°
0.05
F002
kA
0.001
F004
°
0.05
F002
kA
0.001
F003
°
0.05
F002
kA
0.001
F004
°
0.05
F002
DEFAULT
0 (Disabled)
0 (SRC 1)
200
B
10
150
20000
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
1250
1250
1250
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
800
1200
10
100
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
1
0
0 (Disabled)
50000
0
50000
-120
50000
120
50000
0
1000
-10
1000
-130
1000
110
0
0
B-41