Changes To The L90 Manual - GE L90 Instruction Manual

Ur series line current differential system
Hide thumbs Also See for L90:
Table of Contents

Advertisement

F.1 CHANGE NOTES
Table F–1: REVISION HISTORY (Sheet 2 of 2)
MANUAL P/N
1601-0081-R3
1601-0081-S1
1601-0081-S2
1601-0081-S3
1601-0081-T1
1601-0081-U1
1601-0081-U2
1601-0081-V1
1601-0081-V2
1601-0081-W1
1601-0081-X1
1601-0081-X2
Table F–2: MAJOR UPDATES FOR L90 MANUAL REVISION X2 (Sheet 1 of 2)
PAGE
PAGE
CHANGE
(X1)
(X2)
All
All
Update
Title
Title
Update
Copyrig
Copyrig
Update
ht
ht
1-3
1-3
Update
1-4
1-4
Update
1-16
1-16
Update
F
2-
2-
Update
2-
2-
Update
3-
3-
Delete
3-4
3-4
Update
3-10
3-10
Updated
3-18
3-18
Update
3-20
3-20
Update
3-24
3-24
Update
3-25
3-25
Update
3-26
3-26
Update
3-26
3-26
Update
3-28
3-28
Update
3-28
3-28
Update
3-29
3-29
Update
3-29
3-29
Update
3-30
3-30
Update
3-31
3-31
Update
3-32
3-32
Update
3-34
3-34
Update
3-35
3-35
Update
3-35
3-35
Update
F-2
L90 REVISION
RELEASE DATE
5.4x
17 October 2007
5.5x
7 December 2007
5.5x
22 February 2008
5.5x
12 March 2008
5.6x
27 June 2008
5.7x
29 May 2009
5.7x
30 September 2009
5.8x
29 May 2010
5.8x
04 January 2011
5.9x
12 January 2011
6.0x
21 December 2011
6.0x
5 April 2012
DESCRIPTION
Changed safety symbols to new standards
Changed part numbers. Removed copyright from title page. Updated ISO 9001 badge.
Changed copyright to GE Multilin Inc. and updated part number
Updated Figure 1-2 UR Concept Block Diagram to version A3
Updated Figure 1-3 UR-Series Scan Operation to version A3
Updated Figure 1-7 Relay Communication Options to version A2
Updated ordering codes
Updated Latching Relay specifications in section 2.2.7 Outputs
Removed references to 9L, 9M, 9P, and 9R modules in table and figure from section 3.2.9 CPU
Communication Ports
Updated Figure 3-5 L90 Vertical Mounting and Dimensions to version A4
Updated Figure 3-12 Typical Wiring Diagram to version A5
Added surge to module 67 in Figure 3-17 Contact Input and Output Wiring
Updated Figure 3-19 Dry and Wet Contact Input Connections to version A5
Changed 100Base-FL to 100Base-FX in Figure 3-24 CPU Module Communications Wiring
Updated Figure 3-25 RS485 Serial Connection to version AA
Updated Figure 3-26 IRIG-B Connection to version A6
Updated Figure 3-27 IRIG-B Repeater to version A2
Updated Figure 3-28 LED and ELED Fiber Modules to version A3
Updated Figure 3-29 Laser Fiber Modules to version A5
Updated Figure 3-30 G.703 Interface Configuration to version A3
Updated Figure 3-31 Typical PIN Interconnection Between Two G.703 Interfaces to version A5
Updated Figure 3-32 G.703 Timing Selection Switch Setting
Updated dip switch figure 842752A1 in section 3.3.4d) G.703 Timing Modes to version A2
Updated Figure 3-36 Typical PIN Interconnection Between Two RS422 Interfaces to version A2
Updated Figure 3-40 RSS422 and Fiber Interface Connection to version A2
Updated Figure 3-41 G.703 and Fiber Interface Connection to version A2
Updated figure 842755A1 in section 3.3.8 IEEE C37.94 Interface to version A2
L90 Line Current Differential System
ECO
URX-251
URX-253
URX-258
URX-260
08-0390
09-0938
09-1165
09-1457
11-2237
11-2227
11-2840
12-3254
F.1.2 CHANGES TO THE L90 MANUAL
APPENDIX F
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents