class-name in this step must be the same as the name of the traffic class created in
Configuring Traffic Classification
In this step, behavior-name must be the same as that specified in
traffic behavior.
Step 4 Run:
quit
Return to the system view.
Step 5 Run:
interface interface-type interface-number
The interface view is displayed.
Step 6 Run:
traffic-policy policy-name inbound
The traffic policy that contains flow mirroring is applied to the interface.
You can repeatedly perform
attributes, passing through multiple interfaces.
----End

7.11.5 Checking the Configuration

Run the following commands to check the previous configuration.
Action
Check information about the
observing port.
Check information about port
mirroring.
Check the flow mirroring
configuration in the traffic policy
on an interface.
If the following results are obtained, the configuration is successful:
l
l
l

7.12 Configuring Remote Flow Mirroring

This section describes how to configure remote flow mirroring.
Issue 01 (2011-07-15)
The observing port is configured properly.
A proper traffic policy is applied to the interface where incoming flows need to be
monitored.
The traffic policy contains a proper traffic classifier and a traffic behavior and the traffic
behavior contains a flow mirroring action.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Rules.
Step 5
and
Step 6
to monitor the incoming flows, with the same
Command
display observe-port
display port-mirroring
display traffic policy interface [ interface-type
interface-number ] [ inbound ]