Mitsubishi Electric Q01UCPU User Manual page 527

Hide thumbs Also See for Q01UCPU:
Table of Contents

Advertisement

(5)
Replacement example of the KEY instruction
(a) Example of device assignment
Before replacement
Application
Numeric input execution
instruction
Input complete flag
Input data area
ASCII code input signal
Strobe signal
If the device numbers in the example above are used for other applications, assign unused device numbers
instead.
(b) Program before replacement
Device
M0
Numeric input execution instruction
M1
Input complete flag
D200 to D203
Input data area
X100 to X107
ASCII code input signal
X108
Strobe signal
Input data area address (BIN32)
(Input data area + 0) address (BIN32)
(Input data area + 1) address (BIN32)
(Input data area + 2) address (BIN32)
For shifting input data
For converting input data
After replacement
Application
M0
M1
D200 to D203
X100 to X107
X108
D210 to D211
D212 to D213
D214 to D215
D216 to D217
D218
D219 to D220
APPENDICES
Device
A
525