The mounting status of each module in the system is set.
Parameter
Item
Type
I/O
Assignment
Model Name
Points
Start XY
Base Model
Name
Power Model
Name
Base
Setting
Extension
Cable
Slots
Switch Setting
446
I/O assignment
Description
No.
Set the type of the mounted module.
Set the model name of the mounted
0400
H
module. (Entered at user's discretion.
Do not use the one for the CPU
module.)
Set the number of points assigned to
each slot.
Set the start I/O number of each slot.
Set the model name of the main base
unit or extension base unit. (Entered
at user's discretion. Do not use the
one for the CPU module.)
Set the model name of the power
supply module on the main base unit
or extension base unit. (Entered at
user's discretion. Do not use the one
0401
H
for the CPU module.)
Set the extension cable name.
(Entered at user's discretion. Do not
use the one for the CPU module.)
Set the number of slots of the main
base unit or extension base unit.
This setting must be done for all base
units.
Set various switches of an intelligent
0407
H
function module.
Setting range
• CPU No.2 to No.4: No.n/Empty
(Set "CPU (Empty)" for the slot
where no CPU module is
mounted.)
• Empty, Input, Hi. Input, Output, I/O
Mix, Intelligent, or Interrupt
Up to 16 characters
0, 16, 32, 48, 64, 128, 256, 512, or
1024 points
0
to FF0
H
H
Up to 16 characters
Up to 16 characters
Up to 16 characters
2, 3, 5, 8, 10, or 12
Refer to the manual for the intelligent
function module used.
Default
Reference
Page 57,
Blank
Section 2.3.2
Page 52,
Blank
Section 2.2.2
Page 141,
Blank
Section 3.10