Furuno FMD-3200 Operator's Manual page 392

Electronic chart display and information system, ecdis
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

APPENDIX 5 ALERT LIST
No.
Text
011
RS485 Communi-
cation Timeout
012
No Signal
013
Sentence Syntax
Error
014
Fan1 Rotation
Speed Lowering
015
Fan2 Rotation
Speed Lowering
016
Fan3 Rotation
Speed Lowering
017
Fan4 Rotation
Speed Lowering
018
LCD Unit
Lifetime Over
019
High Temperature
Inside Monitor
020
Fan1 No
Rotation
021
Fan2 No
Rotation
AP-34
Default
Meaning
Caution
For MU-190/231: Connect-
ed to COM1. There has
been no communication
from processor unit through
RS485 for 180 seconds.
(No communication implies
in completed sentence or
checksum error.)
Caution
For MU-190/231: Connect-
ed to COM1. There has
been no signal continuously
for 60 seconds.
Caution
For Main monitor, connect-
ed to COM1, value of exter-
nally input sentence is out of
range that defined by sen-
tence.
Caution
For MU-190/231: Connect-
ed to COM2 (Sub Monitor).
Fan1 rotation speed is be-
low threshold.
Caution
For MU-231: Connected to
COM2 (Sub Monitor).
Fan2 rotation speed is be-
low threshold.
Caution
For MU-231: Connected to
COM2 (Sub Monitor).
Fan3 rotation speed is be-
low threshold.
Caution
For MU-190: Connected to
COM2 (Sub Monitor).
Fan4 rotation speed is be-
low threshold.
Warning
For MU-190: Connected to
COM2 LCD unit operating
time exceeds 50000 hours.
For MU-231: Connected to
COM2 LCD unit operating
time exceeds 50000 hours.
Warning
Internal temperature
exceeds threshold.
Monitor: Connected to
COM2 (Sub Monitor).
Warning
For MU-190/231: Connect-
ed to COM2 (Sub Monitor).
Fan1 rotation speed is be-
low threshold.
Warning
For MU-190/231: Connect-
ed to COM2 (Sub Monitor).
Fan2 rotation speed is be-
low threshold.
Remedy
Check the connection of
brightness control cable.
Check the connection of
video cable.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
LCD unit replacement is
required. Contact
FURUNO.
Please turn off monitor.
If the error frequently oc-
curs, contact FURUNO and
inform frequency of occur-
rence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.

Advertisement

Table of Contents
loading

This manual is also suitable for: