Appendix 3 Digital Interface - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system, ecdis
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

APPENDIX 3 DIGITAL INTERFACE

Digital Interface
Input sentence
ABK, ALR, CUR, DBT, DPT, DTM, ETL, GGA, GLL, GNS, HDT, HTD, MTW, MWV, NRX, OSD,
PRC, RMC, ROT, RPM, RSA, RSD, THS, TLL, TRC, TRD, TTM, VBW, VDM, VDO, VDR, VHW,
VTG, XDR, XTE, ZDA
Output sentences
ABM, ACK, BBM, EVE, HTC, OSD, VBW, VSD, XTE
Data reception
Data is received in serial asynchronous form in accordance with the standard referenced in
IEC 61162-2.
The following parameters are used:
Baud rate: 38,400 bps (HDT, THS, !AIVDM, !AIVDO, !AIABK, $AIALR). The baud rate of all other
sentences is 4800 bps
Data bits: 8 (D7 = 0), Parity: none, Stop bits: 1
D0
D1
Start
bit
Data Sentences
Input sentences
ABK - UAIS Addressed and binary broadcast acknowledgement
$**ABK,xxxxxxxxx,x,x.x,x,x,*hh<CR><LF>
1
2 3 4 5
1. MMSI of the addressed AIS unit (9 digits)
2. AIS channel of reception (No use)
3. Message ID (6, 8, 12, 14)
4. Message sequence number (0 - 9)
5. Type of acknowledgement (See below)
1 = message was broadcast (6 or 12), but not ACK by addressed AIS unit
2 = message could not be broadcast (quantity of encapsulated data exceeds five slots)
3 = requested broadcast of message (8, 14 or 15) has been successfully completed
4 = late reception of message (7 or 13) ACK that was addressed to this AIS unit (own ship
and referenced a valid transaction
5 = message has been read and acknowledged on a display unit.
AP-18
D2
D3
D4
D5
Data bits
D6
D7
Stop
bit

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmd-3300Fmd-3200-bb

Table of Contents