Furuno FMD3100 Installation Manual
Hide thumbs Also See for FMD3100:
Table of Contents

Advertisement

Installation Manual
ECDIS
FMD-3100
Model
(ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM)
Safety Instructions ................................................................................................ i
System Configuration ........................................................................................... ii
Equipment List .......................................................................................................... iv
1. MOUNTING..............................................................................................................1-1
1.1 Panel Computer Unit (PCU-3000) .....................................................................................1-1
1.2 Trackball Control Unit (RCU-030) ......................................................................................1-8
1.3 Sensor Adapter MC-3000S/3020D/3030D (Optional)......................................................1-10
1.4 Intelligent Hub HUB-3000 (Optional) ...............................................................................1-11
1.5 Mounting the Switching Hub HUB-100 (Optional)............................................................1-12
1.6 Radar Connection Box RCB-002 (Optional) ....................................................................1-13
2. WIRING....................................................................................................................2-1
2.1 Panel Computer Unit PCU-3000........................................................................................2-3
2.2 Sensor Adapters (Optional) .............................................................................................2-11
2.3 Intelligent HUB HUB-3000 (Optional) ..............................................................................2-27
2.4 Radar Connection Box RCB-002 (Optional) ....................................................................2-28
Appendix 1 Jis Cable Guide .............................................................................AP-1
Appendix 2 Rod Terminals .............................................................................AP-2
Appendix 3 Digital Interface ........................................................................AP-7
Appendix 4 Ra/If Board Jumper Values ...................................................AP-20
Packing ListS ......................................................................................................... A-1
OUTLINE DRAWINGS ................................................................................................ D-1
Interconnection Diagrams.............................................................................. S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FMD3100

  • Page 1 APPENDIX 3 DIGITAL INTERFACE ................AP-7 APPENDIX 4 RA/IF BOARD JUMPER VALUES ...........AP-20 PACKING LISTS ......................A-1 OUTLINE DRAWINGS ....................D-1 INTERCONNECTION DIAGRAMS................S-1 www.furuno.com All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
  • Page 2 The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN A : FEB 2014 Printed in Japan All rights reserved. D1 : NOV . 01, 2016 Pub. No. IME-44840-D1 ( REFU ) FMD-3100...
  • Page 3 SAFETY INSTRUCTIONS The installer of the equipment must read the safety instructions before attempting to install the equipment. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, CAUTION can result in minor or moderate injury.
  • Page 4: Mc-3030D Intelligent Hub Hub

    SYSTEM CONFIGURATION Single workstation Trackball Control Unit RCU-030 Serial interface Switching Hub Sensor Adapter HUB-100 MC-3000S 24 VDC USB DVD Drive Keyboard Digital IN interface 100-230 VAC Sensor Adapter 5139U (Black) MC-3020D External Monitor* , VDR* PANEL Digital OUT interface Sensor Adapter COMPUTER USB Printer,...
  • Page 5: Switching Hub Hub

    SYSTEM CONFIGURATION Multiple workstations (Maximum 3) Trackball Control Unit RCU-030 USB DVD Drive Keyboard 5139U (Black) External Monitor* , VDR* USB Printer, USB Flash Drive Serial Interface (4 ports): • IEC 61162-1/2x2 (AIS, GYRO) • IEC 61162-1x2 (GPS, LOG) PANEL PANEL Switching Hub 100-230VAC...
  • Page 6 001-187-480-10 Between sensor adapters, 1 m MC1.5-W-L2000 001-187-490-10 Between sensor adapters, 2 m Cable Assy. MC1.5-W-L3000 001-187-500-10 Between sensor adapters, 3 m MJ-A10SPF0020A-050+ 001-283-370-00 For Non-FURUNO radars (5 m) MJ-A10SPF0020A-100+ 001-283-380-00 For Non-FURUNO radars (10 m) MJ-A10SPF0020A-200+ 001-283-390-00 For Non-FURUNO radars (20 m) MJ-A10SPF0020A-300+...
  • Page 7: Mounting

    MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. Panel Computer Unit (PCU-3000) The PCU-3000 can be flush-mounted or desktop mounted (optional). Mounting considerations When selecting a desktop mounting location, keep the following points in mind: •...
  • Page 8: Outline Drawings

    1. MOUNTING 1.1.1 Flush mounting Items to prepare for the flush mounting procedure: • Torx screwdriver: T10, T25. 1. Attach the USB cable clamp to the PCU using the torx screws (M34, 2 pcs, included). USB cable clamp USB3 USB1 Attach the USB3 USB1...
  • Page 9 1. MOUNTING 1.1.2 Desktop mounting (optional) Items to prepare for the procedure: • Torx screwdriver: T10, T25. 1. Attach the USB cable clamp to the PCU using the torx screws (M34, 2 pcs, included). USB cable clamp USB3 USB1 Attach the USB3 USB1 USB4...
  • Page 10 1. MOUNTING 5. Referring to the figure below, tilt the PCU 90° rearwards by unlocking the brackets. Hold the unit in place, then pull and turn the locking pins clockwise, one at a time, to set the pin in the unlock position. Locking pin Pull and turn clockwise...
  • Page 11 1. MOUNTING 1.1.3 How to attach the hood (Optional) To install the optional hood (OP24-40), do the following: 1. Referring to the figure below, fit the hood reinforcement fixture to the back of the PCU-3000. For flush-mounting: Install the hood fixing fixture with the flush mount brackets. For desktop mounting: Install the hood fixing fixture with the desktop mount brackets.
  • Page 12 1. MOUNTING 3. Using the cutouts in the hood, set the hood in place between the knobs and the hood fixing fixture. Hood Cutouts Cutouts 4. Referring to the figure below, push the hood down to align the cutouts with the knobs.
  • Page 13 1. MOUNTING 1.1.5 How to replace the USB dongle, CFAST memory card or SSD Referring to the table below, prepare the necessary tools to replace the USB dongle, CFAST memory card or SSD. Part Tool Type USB dongle Torx screwdriver CFAST memory card Philips-head screwdriver Replacing the USB dongle...
  • Page 14: Trackball Control Unit (Rcu-030)

    1. MOUNTING Trackball Control Unit (RCU-030) The Trackball Control Unit (RCU-030) can be mounted on a desktop in two configurations. • Desktop with mounting plate (Standard installation) • Flush mounted inside a console (Optional) Mounting considerations When selecting a mounting location, keep the following points in mind: •...
  • Page 15 1. MOUNTING 1.2.2 Flush mounting (optional) You can use the optional FM FIXTURE ASSEMBLY kit (OP24-38) to flush-mount the unit. Type: OP24-38, Code No.: 001-263-190 Name Type FM Fixture Assembly OP24-38-1 Washer Head Screw M410 Note: The flush mount location must have a thickness of at least 10 mm, with a max- imum thickness of 20 mm.
  • Page 16: Sensor Adapter Mc-3000S/3020D/3030D (Optional)

    1. MOUNTING Sensor Adapter MC-3000S/3020D/3030D (Optional) Mounting considerations When you select a mounting location, keep in mind the following points: • Locate the equipment away from heat sources because of heat that can build up inside the cabinet. • Take into account the length of the cables to connected to the equipment when choosing an installation location.
  • Page 17: Intelligent Hub Hub-3000 (Optional)

    1. MOUNTING Intelligent Hub HUB-3000 (Optional) Use the optional Intelligent Hub HUB-3000 to connect gateway network equipment. This network cannot be connected with the LAN network on board. Note that a commercial PC cannot be connected to this network, other than for maintenance. Mounting considerations Keep the following points in mind when selection a mounting location: •...
  • Page 18: Mounting The Switching Hub Hub-100 (Optional)

    1. MOUNTING Mounting the Switching Hub HUB-100 (Optional) Use the optional Switching HUB HUB-100 to connect sensor networks. This network cannot be connected with the LAN network on board. Note that a commercial PC can- not be connected in this network, other than for the maintenance. For the mounting procedures, see the operator’s manual for HUB-100 (Pub.
  • Page 19: Radar Connection Box Rcb-002 (Optional)

    1. MOUNTING Radar Connection Box RCB-002 (Optional) You can display signals from up to two external radars on the FMD-3100 by using the RCB-002. The RCB-002 must be connected via the Gateway Network. Mounting considerations Keep the following points in mind when selection a mounting location: •...
  • Page 20 1. MOUNTING This page is intentionally left blank. 1-14...
  • Page 21: Wiring

    WIRING The illustration on this page shows the general connection between FMD-3100 and external equipment. For detailed information, see the interconnection diagram at the back of this manual. Many of the cables mentioned are JIS (Japan Industry Standard) cables. If not available locally, use the equivalent. See the cable guide in the Appendix for how to select equivalent cables.
  • Page 22 • The Switching HUB HUB-100 does not support IGMP snooping or GCMP enabled switch. • When you use IEC61162-450 compatible sensors, set [Transmission Group] on the [Common Installation Settings] menu. Only service technicians can access the [Common Installation Settings] menu. Contact your FURUNO dealer to set it.
  • Page 23: Panel Computer Unit Pcu-3000

    2. WIRING Panel Computer Unit PCU-3000 2.1.1 Connections to the PCU-3000 Referring to the figure below, connect the PCU to its respective peripherals. DVI-D To external monitor : AC and DC input cannot DVI-D/D S-LINK5M cable be used simultaneously USB1 to 4 24 VDC Grounding point for serial ports (Used when flushmounting only)
  • Page 24 2. WIRING 2.1.2 Connecting the flush mountable USB Extension Cable You may require an extension from the USB port on the PCU. A 1m length USB extension cable is included with the PCU. When using another USB extension cable, make sure the total length is shorter than 5 m. Cap strap USB extension cable You can connect the flush-mounted extension cable by doing the following:...
  • Page 25 2. WIRING 5. Place the cap strap, then tighten the nut to secure the cable. See the figure below. Installation point - console, etc. Note: Always screw the cap on when the extension cable is not in use. 2.1.3 Fabricating the power cables When using AC power, connect the unit with the supplied AC power cables.
  • Page 26 2. WIRING 2.1.4 Fabricating LAN cables Fabricate the LAN cable (FR-FTPC-CY, DTI-C5E350 VCV), as shown below. (Wrap both edges of the armor with vinyl tape.) Confirm that the shield of the cable touches to the shell of the modular plug. Shielding Cable jacket Inner sheath...
  • Page 27 2. WIRING 2.1.5 Fabricating JIS cables Fabricate JIS cables as shown below to connect them to the WAGO connectors on the PCU-3000 (See following page for WAGO connection). After fabricating the cable, attach the WAGO connector and EMI ferrite core (sup- plied).
  • Page 28 2. WIRING How to connect the JIS cables to the WAGO connectors WAGO connectionfor IEC161162-1 lines WAGO connectionfor IEC161162-2 lines P4 & P5 WAGO connector screw WAGO connector screw Wire Wire Twist Resistor <Procedure> <Procedure> 1. Twist the core wire. 1.
  • Page 29 2. WIRING How to set input specifications for WAGO connection (C1 to C4) Port Signal Description IEC61162-2 IEC61162-1 TxD- Serial CH1,Output IEC61162-1/2 TTYCS(LA)-4 TTYCS(LA)-1Q TxD+ Serial CH1,Output IEC61162-1/2 ISOGND Isolation GND (CH1) No connection RxD- Serial CH1,Input IEC61162-1/2 TTYCS(LA)-1Q RxD+ Serial CH1,Input IEC61162-1/2 TxD- Serial CH2,Output IEC61162-1/2 TTYCS(LA)-4 TTYCS(LA)-1Q...
  • Page 30 2. WIRING 2.1.6 Securing cables to the cable clamp When installing the unit with the desktop option, use the cable clamp to secure the electrical wiring and LAN cables. Cable clamp When not using the cable clamp, drain wires must be connected to the grounding point on the PCU-3000 (See the figure in paragraph 2.1.1).
  • Page 31: Sensor Adapters (Optional)

    2. WIRING Sensor Adapters (Optional) Maximum eight MC-3000S can be connected to a sensor network (for the redundant connection: 16). The MC-3000S (serial input/output, IEC61162-2/1, 4ch) can connect max. 10 sensor adapters using the MC1.5-W cables. To connect the lines to the connector on the sensor adapter, use the rod terminal (fer- rule type, supplied) to maintain performance.
  • Page 32 2. WIRING 2.2.1 MC-3000S connections Unfasten four screws to remove the cover, pass the cables through the clamps and attach the cables to respective connectors. The shield part of the cable (or drain wire) must be fastened by (connected to) the clamp. For TTYCSLA cables, pass the drain wire into the shrinking tube (local supply), then use these crimp-on lugs and screws...
  • Page 33 2. WIRING How to set input specification (J4 to J9) For connectors J4 to J7, the connections are different depending on the input specifications as shown below. Also, for J8 and J9, the signals which are input/output are shown. Connector J4 Signal In/Out Description...
  • Page 34 2. WIRING Connector J6 Signal In/Out Description IEC61162-2 IEC61162-1 name TD3-A Serial CH3, output IEC61162-1/2 TTYCS(LA)-4 TTYCS(LA)-4 TD3-B Serial CH3, output IEC61162-1/2 RD3-A Serial CH3, input IEC61162-2 No connection RD3-B Serial CH3, input IEC61162-2 ISOGND3 Isolation, GND (CH3) RD3-H Serial CH3, input IEC61162-1 No connection TTYCS(LA)-4 RD3-C Serial CH3, input IEC61162-1...
  • Page 35 2. WIRING 2.2.2 MC-3000S connection fabrications Fabricate the cables to be connected to the MC-3000S referring to the figure below. LAN cable (FR-FTPC-CY) MC1.5-W-L600/1000/2000/3000 cable See section 2.1.4 for See section 2.1.4 for See section 2.1.4 for Core: 6 Core: 6 Core: 6 Shield Shield...
  • Page 36 2. WIRING TTYCSLA-1 cable TTYCS-1 cable Core: 6 Core: 6 Core: 6 Core: 6 Core: 6 Core: 6 Vinyl tape Vinyl tape Vinyl tape Shield (fold back) Shield (fold back) Shield (fold back) Vinyl tape Vinyl tape Vinyl tape (width: 10) (width: 10) (width: 10) (width: 10)
  • Page 37 2. WIRING 2.2.3 MC-3000S Jumper and MODBUS settings Set the jumper blocks in the MC-CS Board (24P0114) referring to the tables that follow. MC-CS Board (24P0114) Setting MODBUS addresses: Use the rotary switch (S2) to set the Modbus address when setting connectors J4/J5 to Modbus. The Modbus address set at J4/J5 in the network is not used.
  • Page 38 2. WIRING (Terminal resistor OFF) • When setting the terminal other than starting/ending for the multipoint (CH1 to 4). • When setting the terminal other than starting/ending for Modbus (CH1/CH2) Jumper block J14 Connector J4 (CH1) SHORT Termination resistor: ON (default setting) OPEN OPEN Termination resistor: OFF...
  • Page 39 2. WIRING 2.2.4 Waterproof case packing for MC-3000S (optional) The optional kit OP24-28 protects the connectors on the MC-3000C to waterproofing standard IPX2. Case packing (type: OP24-28, code no.: 001-169-970) Name Type Code No. Remarks Case packing (serial) 21-014-2051 100-367-880-10 2 For MC-3000S 1.
  • Page 40 2. WIRING 2.2.5 MC-3020/3030D connections • MC-3020D: Inputs digital signal (8ch contact input). Contact or voltage input is se- lectable (contact input requires jumper pins). • MC-3030D: Outputs digital signal (8ch, normal open/close). IV-1.25sq. (Local supply) IV-1.25sq. (Local supply) MPYC-12 MPYC-12 MC1.5-W-L cable MC1.5-W-L cable...
  • Page 41 2. WIRING How to set ACK input (MC-3020D) Use the connectors J3 to J6 on the MC-DIN Board (24P0116) to set the ACK input for ACK1 to ACK8 as shown below. • Input circuit for voltage input 470Ω/ 0.5W Register DC12V_OUT 2.2kΩ...
  • Page 42 2. WIRING Connector J4 ACK3 ACK4 ACK4 Pin # Signal name Remarks ACK3 voltage contact contact voltage DC12V_OUT Pin #1-#2: No connection short DIGI_IN3 MPYC-12 ACK3 In Depending on ACK3 input- DIGI_RTN3 MPYC-12 GND (DC12V) In No connection DC12V_OUT Pin #1-#2: No connec- short tion...
  • Page 43 2. WIRING How to set alarm output (MC-3030D) Use the connector J3 to J6 on the MC_OUT Board (24P0117) to select NC (normal close) or NO (normal open) for alarm output 1 to 8. Connector J3 Signal Alarm1 NO Alarm1 NC Alarm2 NO Alarm2 NC Remarks...
  • Page 44 2. WIRING 2.2.6 Cable fabrication for MC-3020D/3030D connections Using the figures below for reference, fabricate the cables to be connected to the MC-3020D/3030D. MC1.5-W-L600/1000/2000/3000 cable MPYC-12 cable (MC-3020D) (Input) 80 or 80 or 80 or more more more Shield Shield Shield Vinyl tape Vinyl tape...
  • Page 45 2. WIRING 2.2.7 How to set jumper blocks in the sensor adapters MC-3020D/3030D This paragraph shows how to set the MC-DIN Board (24P0116, for MC-3020D) and MC-DOUT Board (24P0117, for MC-3030D). Setting MODBUS addresses: Use the rotary switch (U18) to set the MODBUS address with a digit of number from “0”.
  • Page 46 2. WIRING 2.2.8 MC-3020D/3030D Waterproof case packing OP24-29 (Optional) The optional kit OP24-29 protects the connectors on the MC-3020D/3030D to waterproofing standard IPX2. Case packing (type: OP24-29, code no.: 001-169-970) Name Type Code No. Remarks Case packing (analog) 21-014-2052-2 100-367-961-10 MC-3020D/3030D 1.
  • Page 47 2. WIRING Intelligent HUB HUB-3000 (Optional) Fix any LAN cables connected to the HUB-3000 to their respective cable clamps using cable ties (supplied). Power port Power Fail DPYC-1.5 cable DPYC-1.5 cable Ground wire (IV-1.25sq., supplied) LAN cable No use. LAN ports to INS network (ECDIS, radar, etc.) Attach the LAN cap (supplied) to the unused connector holes to provide waterproofing standard IPX2.
  • Page 48 2. WIRING Radar Connection Box RCB-002 (Optional) The RCB-002 is capable of connecting the FMD-3100 with up to two external radar systems. Referring to the figure and table below, connect the respective equipment to the RCB-002. RADAR SIGNAL IN No.1 To external radar MJ-A10SPF0020A (5m, 10 m, 20 m, 30 m) cable RADAR SIGNAL IN No.2...
  • Page 49 2. WIRING 2. Dismantle the seal assembly as shown below. Dismantling the seal assembly STEP 1: Hold the fat end of the seal assembly with both thumbs while placing the index fingernails between the seal and the claw. Use caution to avoid injury. STEP 2: Using the thumbs, gently push the seal out of the claw.
  • Page 50: Model

    Tokyo Keiki Inc. BR-3440 series • Model 1835 *: FURUNO radars are only compatible with the CH2 (RADAR SIGNAL IN NO.2 port). Change the jumper settings on the RA/IF board (24P0140) according to the radar to be connected, referring the tables on the next page.
  • Page 51 Using the table below for reference, change the jumper settings to suit the appropriate radar connection. Use the figure on the previous page for jumper locations. Radar to be connected Jumper FURUNO radars JMA-9100 series BR-3440 series #2-3: short #1-2: short...
  • Page 52 2. WIRING This page is intentionally left blank. 2-32...
  • Page 53: Appendix 1 Jis Cable Guide

    EX: TTYCYSLA - 4 MPYC - 4 TTYCSLA-4 Core Area (mm Designation type Designation type # of cores The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Core Cable Diameter Diameter...
  • Page 54: Appendix 2 Rod Terminals

    APPENDIX 2 ROD TERMINALS MC-3000S, MC-CS Board (24P0114) Connector # Pin # Signal name Rod terminal to use Connected cable 24V_VOUT AI 0.34-6 TQ (blue) 24V_GND MODBUS-A AI 0.14-8 GY (gray) MC1.5-W-Lxxx MODBUS-B Connector # Pin # Signal name Rod terminal to use Connected cable 24V_IN AI 1.5-6 BK (black)
  • Page 55 APPENDIX 2 ROD TERMINALS Connector # Pin # Signal name Rod terminal to use Connected cable TD4-A TD4-B RD4-A TTYCS-4 RD4-B AI 0.75-6 GY (gray) TTYCSLA-4 ISOGND4 RD4-H RD4-C Connector # Pin # Signal name Rod terminal to use Connected cable TD5-A TD5-B TTYCS-1Q...
  • Page 56 APPENDIX 2 ROD TERMINALS MC-3020D, MC-DIN Board (24P0116) Connector # Pin # Signal name Rod terminal to use Connected cable 24V_IN AI 0.34-6 TQ (blue) 24V_GND MODBUS-A AI 0.14-8 GY (gray) MC1.5-W-Lxxx MODBUS-B Connector # Pin # Signal name Rod terminal to use Connected cable 24V_OUT AI 0.34-6 TQ (blue)
  • Page 57 APPENDIX 2 ROD TERMINALS Connector # Pin # Signal name Rod terminal to use Connected cable DV12V_OUT5 DIGI_IN5 DIGI_RTN5 AI 1-6 RD (red) MPYC-12 DC12V_OUT6 DIGI_IN6 DIGI_RTN6 *: Pin #1 and 5: no cable connection. However the jumper connection is necessary between #1 and 2 and #5 and 6 depending on the input specification.
  • Page 58 APPENDIX 2 ROD TERMINALS MC-3030D, MC-DOUT Board (24P0117) Connector # Pin # Signal name Rod terminal to use Connected cable 24V_IN AI 0.34-6 TQ (blue) 24V_GND MODBUS-A AI 0.14-8 GY (gray) MC1.5-W-Lxxx MODBUS-B Connector # Pin # Signal name Rod terminal to use Connected cable 24V_OUT AI 0.34-6 TQ (blue)
  • Page 59: Appendix 3 Digital Interface

    TTD,TTM, VBW, VDM, VDO, VDR, VHW, VSD, VTG, XDR, ZDA Output sentences ABM, ACK, ACN, ALC, ALF, ARC, BBM, DDC, EVE, HBT, OSD, RRT, VBW, VDR, VSD, XTE FURUNO proprietary output sentence PFEC (pidat, pireq, llco, llmba, rminf, rmset, rmevt) Data reception Data is received in serial asynchronous form in accordance with the standard referenced in IEC 61162-2.
  • Page 60 APPENDIX 3 DIGITAL INTERFACE ACN - Alert command $**ACN,hhmmss.ss,aaa,x.x,x.x,c,a*hh<CR><LF> 4 5 6 1. Time (UTC) 2. Manufacturer mnemonic code (3 digits) 3. Alert Identifier (0 - 9999999) 4. Alert Instance (1 - 999999,null) 5. Alert command (A,Q,O,S) A=acknowledge Q=request/repeat information O=responsibility transfer S=silence 6.
  • Page 61 APPENDIX 3 DIGITAL INTERFACE ARC - Alert command refused $**ARC,hhmmss.ss,aaa,x.x,x.x,c*hh<CR><LF> 3 4 5 1. Release time of the Alert Command Refused(UTC) 2. Used for proprietary alerts, defined by the manufacturer 3. The alert identifier(1 - 9999999) 4. The alert instance(1 to -99) 5.
  • Page 62 APPENDIX 3 DIGITAL INTERFACE ETL - Engine telegraph operation status $**ETL,hhmmss.ss,a,xx,xx,a,x*hh<CR><LF> 2 3 4 5 6 1. Event time (UTC) 2. Message type (O=order A=answerback) 3. Position indicator of engine telegraph 00 = Stop engine 01 = [AH] Dead Slow 02 = [AH] Slow 03 = [AH] Half 04 = Full...
  • Page 63 APPENDIX 3 DIGITAL INTERFACE GNS - GNSS fix data $--GNS,hhmmss.ss,llll.lll,a,IIIII.III,a,c--c,xx,x.x,x.x,x.x,x.x,x.x,a*hh<CR><LF> 7 8 9 10 11 1213 1. UTC of position (no use) 2. Latitude (0000.00000 - 9000.00000) 3. N/S 4. Longitude (0000.00000 - 18000.00000) 5. E/W 6. Mode indicator (P, R, D, F, A, E, M, S) N=No fix A=Autonomous D=Differential P=Precise R=Real Time Kinematic F=Float RTK E=Estimated Mode M=Manual Input Mode S=Simulator Mode 7.
  • Page 64 APPENDIX 3 DIGITAL INTERFACE NRX - Navtex received data $--NRX,xxx,xxx,xx,aaxx,x,hhmmss.ss,xx,xx,xxxx,x.x,x.x, A,c--c*hh<CR><LF> 10 11 12 13 1. Number of sentences (001 to 999) 2. Sentence number (001-999) 3. Sequential message ID (00 to 99) 4. Navtex message code (aaxx aa: AA to ZZ xx: 00 to 99) 5.
  • Page 65 APPENDIX 3 DIGITAL INTERFACE RMC - Recommended minimum specific GPS/TRANSIT datas $--RMC,hhmmss.ss,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,ddmmyy,x.x,a,a,a*hh<CR><LF> 2 3 4 6 7 8 10 11 1213 1. UTC of position fix (000000 - 235959) 2. Status (A=data valid, V=navigation receiver warning) 3. Latitude (0000.00000 - 9000.0000) 4.
  • Page 66 APPENDIX 3 DIGITAL INTERFACE RRT - Report route transfer $**RRT, a, c-c, c-c, c-c, a, a *hh <CR><LF> 4 5 6 1. Reported transfer type. (M=Monitored route, A=Alternative route for editing, Q=Query for transmitting any monitored or alternative route for editing) 2.
  • Page 67 APPENDIX 3 DIGITAL INTERFACE TRC - Thruster control data $**TRC,x,x.x,a,x.x,a,x.x, a,a*hh<CR><LF> 1 2 3 4 5 6 7 8 1. Number of thruster, bow or stern (01 to 99) 2. RPM demand value (-999.9 to 999.9) 3. RPM mode indicator (P=per cent R=revolutions per min V=data invalid) 4.
  • Page 68 APPENDIX 3 DIGITAL INTERFACE VBW - Dual ground/water speed $--VBW,x.x,x.x,x,x.x,x.x,x,x.x,x,x.x,x*hh<CR><LF> 1 2 3 4 5 6 7 8 9 10 1. Longitudinal water speed, knots (-9999.999 - 9999.999) 2. Transverse water speed, knots (-9999.999 - 9999.999, null) 3. Status: water speed, A=data valid V=data invalid 4.
  • Page 69 APPENDIX 3 DIGITAL INTERFACE VSD - UAIS Voyage static data $--VSD,x.x,x.x,x.x,c--c,hhmmss.ss,xx,xx,x.x,x.x*hh<CR><LF> 6 7 8 1. Type of ship and cargo category (0 - 255) 2. Maximum present static draught (0 to 25.5 meters, null) 3. Persons on-board (0 - 8191, null) 4.
  • Page 70 APPENDIX 3 DIGITAL INTERFACE Output sentences See input sentences for ACN, ALC, ALF, ARC, HBT, OSD, RRT, VBW, VDR and VSD. ABM - UAIS Addressed binary and safety related message !--ABM,x,x,x,xxxxxxxxx,x,x.x,s--s,x*hh<CR><LF> 1 2 3 1. Total number of sentences needed to transfer the message (1 - 9) 2.
  • Page 71 APPENDIX 3 DIGITAL INTERFACE Serial Interface TD-A TD-B LTC1535 ISOGND RD-A RD-B 110 ohm* * Set with jumper. 470 ohm Switchable open/close. RD-H PC-400 RD-C Sensor Adapter: IEC 61162-2/1 input/output 470 ohm RD-H PC-400 RD-C Sensor Adapter: IEC 61162-1 input 10 ohm 10 ohm TD-A...
  • Page 72: Appendix 4 Ra/If Board Jumper Values

    APPENDIX 4 RA/IF BOARD JUMPER VALUES The values for each jumper block on the RA/IF board (24P0140) are shown below. CH1/CH2 signal settings J10/J22 TRG-TERM J1/J8 HD-TERM J3/J16 VID-TERM J5/J18 BP-TERM 1.2 kΩ 75Ω 1.2 kΩ 50Ω 50Ω 75Ω 180kΩ 1.2 kΩ...
  • Page 74: Cp24

    001-262-570-00 24AN-X-9401 CODE NO. TYPE CP24-03101 工事材料表 INSTALLATION MATERIALS 数量 番 号 名  称 型名/規格 略  図 用途/備考 Q'TY OUTLINE NAME DESCRIPTIONS REMARKS コンベックス CV-100N CABLE TIE CODE NO. 000-162-167-10 圧着端子 FV1.25-4(LF) RED CRIMP-ON LUG CODE NO. 000-166-666-10 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT. QUALITY IS THE SAME.
  • Page 79 11/Dec/2013 H.MAKI...
  • Page 80: Mj-A10Spf0020A

    IEC61162-1/2 IEC61162-1 ネットワーク機器 STP(CAT5) CABLE NETWORK EQUIPMENT パネルPC部 スイッチングハブ *2 *3 PANEL COMPUTER UNIT FR-FTPC-CY, SWITCHING HUB LAN2 PCU-3000 10/20/30m,φ13 HUB-100 (8 PORTS) または センサーアダプター IV-1.25sq. SENSOR ADAPTER MC-3000S(SERIAL 8ch) PCA100293 MC-3020D(DIGITAL IN) MC-3030D(DIGITAL OUT) (詳細はC4473-C02を参照) (REFER TO C4473-C02 FOR DETAIL) IV-2sq.
  • Page 81 選択 SELECT 制御部 センサーアダプター PROCESSOR SENSOR ADAPTER UNIT MC-3000S(SERIAL 8ch) EC-3000 パネルPC部 PANEL COMPUTER UNIT PCU-3000 または OR スイッチングハブ SWITCHING HUB HUB-100 IV-1.25sq. 3-4間ジャンパー設定 オープン:電圧入力、ショート:電流入力 JUMPER SETTING BETWEEN 3 AND 4; OPEN: VOLTAGE INPUT, CLOSE: CURRENT INPUT IV-1.25sq. IV-1.25sq. 注記 *1)造船所手配。...

This manual is also suitable for:

Ecdis fmd-3100

Table of Contents