HW0486052
DX100
6.2
6
Data Protection
6.2

Operation When VERIFY ERROR Occurs

Operation When VERIFY ERROR Occurs
If the following alarm occurs when the control power is turned ON,
Alarm 0300: "VERIFY ERROR(SYSTEM CONFIG-DATA)[10]"
perform the following operations to re-set the data of the functional safety
unit.
1. When the controller power is turned ON,
Alarm 0300: "VERIFY ERROR(SYSTEM CONFIG-DATA)[10]" occurs
and the maintenance mode is started up.
– Select {SYSTEM} under the main menu. Then, change the security
mode from EDIT MODE to MANAGEMENT MODE with the
procedure described in chapter 3.1 "Changing Security Mode" at
page 3-1.
2. Select {FILE} under the main menu. Then, select {INITIALIZE} under
the sub menu.