6

Data Protection

6.1
6
Data Protection
6.1

Saving Dual Data

Saving Dual Data
The data related to this function is saved in a duplicated manner for safety.
When the control power is turned ON, check is performed to see that dual
data sets are the same.
If they are different when the control power is turned ON, the following
alarm occurs.
When the following alarm occurs, set up data according to the procedure
described in chapter 6.2 "Operation When VERIFY ERROR Occurs" at
page 6-2.
Alarm 0300: "VERIFY ERROR(SYSTEM CONFIG-DATA)[10]"
If the alarm occurs, the following causes are possible:
• The data related to this function is loaded from an external storage.
• The home position calibration or the home position change operation
is performed.
• The tool calibration operation is performed.
• The data saving has not been performed correctly.