YASKAWA DX100 Instructions Manual page 38

Hide thumbs Also See for DX100:
Table of Contents

Advertisement

HW0486052
DX100
4
Setup (Safety Range Function for Each Axis)
4.3
Setting Safety Range for Each Axis
2. Select {AXIS RANGE} under the sub menu.
– The AXIS RANGE screen is displayed.
<Description of the screen>
CTRL GROUP: Selects a control group to be set in the case of a multiple
control group system.
To set S1, move the cursor to "S1" and press [SELECT].
SETTING: Sets the safety range limit function (for each axis) status.
Status
Detail
INVALID
The safety range function for each axis can be disabled
temporarily.
VALID
The safety range function for each axis is enabled.
STATUS: Indicates the status: SETTING or CONFIRMING or
MONITORING.
Status
Contents
SETTING
"SETTING" is displayed when setting the data.
CONFIRMING
"CONFIRMING" is displayed when confirming the range
after data setting.
MONITORING
"MONITORING" is displayed after confirming the data.
While "MONITORING" is displayed, the safety range
function for each axis is performed.
4-5