Examples of parameters used with different makers and types of printers (reference)
Name
Kodak MLP190
Kodak KELP2180 +
Kodak Print Spooler
Model 100
Agfa DryStar 3000
Kodak Imation DryView
8700 + Pacs LINK IMN
9410
Kodak Imation DryView
8700 + GW
Kodak Imation DryView
8700+8800
2. Installation Manual
Default Parameters
-A 320 -T NO -M CUBIC –m
NORMAL -S CS000
(entered in param member)
80 (entered in pixelPitch
member)
14 x 17
4096 (entered in W member)
5120 (entered in H member)
-A 320 -T NO -M CUBIC –m
NORMAL -S CS000
(entered in param member)
79 (entered in pixelPitch
member)
14 x 17
4090 (entered in W member)
5120 (entered in H member)
11 x 14
3194 (entered in W member)
4096 (entered in H member)
-A 320 -T NO -M CUBIC -m
140 -S
"PERCEPTION_LUT=200"
(entered in param member)
80 (entered in pixelPitch
member)
14x17
4256 (entered in W member)
5174 (entered in H member)
-A 310 -T NO -M CUBIC -
m ? -S LUT=0?, 2? (?: Site
Dependent)
(entered in param member)
78 (entered in pixelPitch
member)
14x17
4096 (entered in W member)
5220 (entered in H member)
-A 310 -T NO -M CUBIC -
m ? -S LUT=?, ? (?: Site
Dependent)
(entered in param member)
78 (entered in pixelPitch
member)
14x17
4096 (entered in W member)
5220 (entered in H member)
-A 320 -T NO -M CUBIC –S
"LUT=m, n"-m (on-site
adjustment)
(entered in param member)
78 (entered in pixelPitch
member)
4096 (entered in W member)
5220 (entered in H member)
- 57 -
Significance
• Trimming OFF
• Cubic spline interpolation
• Smoothing: normal
• Maximum density: 3.20
• Curve shape 0 (density linear) as Config
Info
• Trimming OFF
• Cubic spline interpolation
• Smoothing: normal
• Maximum density: 3.20
• Curve shape 0 (density linear) as Config
Info
• Trimming OFF
• Cubic spline interpolation
• Smoothing: slightly sharp (edges
emphasized)
• Maximum density: 3.20
• S
"PERCEPTION_LUT=200(LINEAR)"
(If the output fails to be linear with
"LINEAR", on-site adjustments with the
printer manufacturer must be performed.
• Trimming OFF
• Cubic spline interpolation
• Smoothing must be adjusted at the user's
site.
• Maximum density: 3.10
• S LUT = m, n is designated as the
Config Info but m and n are adjusted on-
site by the Kodak service engineer.
Basically, adjustment is performed to
achieve a linear output.
• Trimming OFF
• Cubic spline interpolation
• Smoothing must be adjusted at the user's
site.
• Maximum density: 3.10
• S LUT = m, n is designated as the
Config Info but m and n are adjusted on-
site by the Kodak service engineer.
Basically, adjustment is performed to
achieve a linear output.
• Trimming OFF
• Cubic spline interpolation
• Maximum density: 3.20
• S LUT = m, n is designated as the
Config Info but m and n are adjusted on-
site by the Kodak service engineer.
Basically, adjustment is performed to
achieve a linear output.