Installation And Start Up; Environmental Conditions - Mitsubishi Electric MR-J2M-P8B Instruction Manual

Table of Contents

Advertisement

2. INSTALLATION AND START UP

2. INSTALLATION AND START UP
CAUTION

2.1 Environmental conditions

The following environmental conditions are common to the drive unit, interface unit and base unit.
Environment
During
operation
Ambient
temperature
In storage
During operation
Ambient
humidity
In storage
Ambience
Altitude
Vibration
Stacking in excess of the limited number of products is not allowed.
Install the equipment to incombustibles. Installing them directly or close to
combustibles will led to a fire.
Install the equipment in a load-bearing place in accordance with this Instruction
Manual.
Do not get on or put heavy load on the equipment to prevent injury.
Use the equipment within the specified environmental condition range.
Provide an adequate protection to prevent screws, metallic detritus and other
conductive matter or oil and other combustible matter from entering each unit.
Do not block the intake/exhaust ports of each unit. Otherwise, a fault may occur.
Do not subject each unit to drop impact or shock loads as they are precision
equipment.
Do not install or operate a faulty unit.
When the product has been stored for an extended period of time, consult
Mitsubishi.
When treating the servo amplifier, be careful about the edged parts such as the
corners of the servo amplifier.
[
]
[
]
[
]
[
]
Free from corrosive gas, flammable gas, oil mist, dust and dirt
2
[m/s
]
2
[ft/s
]
www.dadehpardazan.ir 88594014-15
Conditions
0 to 55 (non-freezing)
32 to 131 (non-freezing)
20 to 65 (non-freezing)
4 to 149 (non-freezing)
90%RH or less (non-condensing)
Indoors (no direct sunlight)
Max. 1000m (3280 ft) above sea level
2
5.9 [m/s
] or less
2
19.4 [ft/s
] or less
2 - 1