11. CHARACTERISTICS
16
14
12
10
053
8
6
4
2
0
0
500 1000 1500 2000 2500 3000
a. HC-KFS series
0.07
0.06
0.05
0.04
0.03
0.02
0.01
0
0
50 500 1000 1500 2000 2500 3000
c. HC-UFS3000r/min series
Use the dynamic brake at the load inertia moment indicated in the following table. If the load inertia
moment is higher than this value, the built-in dynamic brake may burn. If there is a possibility that the
load inertia moment may exceed the value, contact Mitsubishi.
23
73
43
13
Speed [r/min]
73
43
23
13
Speed [r/min]
Fig. 11.4 Dynamic brake time constant
Drive unit
MR-J2M-10DU
MR-J2M-20DU
MR-J2M-40DU
MR-J2M-70DU
www.dadehpardazan.ir 88594014-15
0.02
0.018
0.016
0.014
0.012
0.01
0.008
0.006
053
0.004
0.002
0
0
500 1000 1500 2000 2500 3000
b. HC-MFS series
Load inertia moment ratio [times]
30
11 - 5
23
43
73
13
Speed [r/min]