5. PARAMETERS
Classifi-
No.
Symbol
cation
9
*SSC
SSCNET type selection
Select the network type of the interface unit.
10
*OP2
Optional function 2
Choose the input signal filter and test operation.
Name and Function
0 2
POINT
When using motion controller Q series, set the communication
cycle according to the motion controller.
The initial settings of communication cycle/number of control
axes of motion controller Q series are as follows:
1. Q173CPU
SV13: SSCNET0.8ms/1 to 8 axes, SSCNET1.7ms/9 to 16
axes, SSCNET3.5ms/17 to 32 axes
SV22: SSCNET0.8ms/1 to 4 axes, SSCNET1.7ms/5 to 12
axes, SSCNET3.5ms/13 to 32 axes
2. Q172CPU
SV13: SSCNET0.8ms/1 to 8 axes
SV22: SSCNET0.8ms/1 to 4 axes, SSCNET1.7ms/5 to 8
axes
The communication cycle of motion controller can be
changed using the parameter.
In the case of MR-J2M, initialization of servo amplifier MR-
J2M (LED indication "@ Ab#" or "@ AC#") will not be
completed, if the communication cycle settings are different
between the motion controller and servo amplifier MR-
J2M.
0
Test operation selection
0: Invalid
1: Valid
Input signal filter
0: No
1: 1.777ms
2: 3.555ms
Electromagnetic brake interlock output axis number selection
Choose the axis number of the drive unit which uses
electromagnetic brake interlock output (MBR).
Setting
All connected axes
0
1
2
3
4
5
6
7
8
www.dadehpardazan.ir 88594014-15
SSCNET type selection
00: SSCNET3.5ms
01: SSCNET1.7ms
02: SSCNET0.8ms
12: SSCNET
Selected Axis
First axis
Second axis
Third axis
Fourth axis
Fifth axis
Sixth axis
Seventh axis
Eighth axis
5 - 19
Initial
Setting
Unit
Value
Range
0200
Refer to
name
and
function
column.
0020
Refer to
name
and
function
column.