4. Additional instructions
The following instructions should also be fully noted. Incorrect handling may cause a fault, injury, electric
shock, etc.
(1) Transportation and installation
Transport the products correctly according to their masses.
Stacking in excess of the specified number of products is not allowed.
Do not carry the servo motor by the cables, shaft or encoder.
Do not hold the front cover to transport each unit. Each unit may drop.
Install the each unit in a load-bearing place in accordance with the Instruction Manual.
Do not climb or stand on servo equipment. Do not put heavy objects on equipment.
The controller and servo motor must be installed in the specified direction.
Leave specified clearances between the base unit and control enclosure walls or other equipment.
Do not install or operate the unit and servo motor which has been damaged or has any parts missing.
Provide adequate protection to prevent screws and other conductive matter, oil and other combustible
matter from entering each unit and servo motor.
Do not drop or strike each unit or servo motor. Isolate from all impact loads.
When you keep or use it, please fulfill the following environmental conditions.
Environment
During
operation
Ambient
temperature
In storage
During
Ambient
operation
humidity
In storage
Ambience
Altitude
(Note)
Vibration
Note. Except the servo motor with reduction gear.
Securely attach the servo motor to the machine. If attach insecurely, the servo motor may come off during
operation.
The servo motor with reduction gear must be installed in the specified direction to prevent oil leakage.
Take safety measures, e.g. provide covers, to prevent accidental access to the rotating parts of the servo
motor during operation.
Never hit the servo motor or shaft, especially when coupling the servo motor to the machine. The encoder
may become faulty.
Do not subject the servo motor shaft to more than the permissible load. Otherwise, the shaft may break.
When the equipment has been stored for an extended period of time, consult Mitsubishi.
[ ] 0 to 55 (non-freezing)
[ ] 32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
[ ]
4 to 149 (non-freezing)
90%RH or less (non-condensing)
Indoors (no direct sunlight) Free from corrosive gas, flammable gas, oil mist, dust and dirt
Max. 1000m (3280 ft) above sea level
2
[m/s
]
5.9 or less
2
[ft/s
]
19.4 or less
www.dadehpardazan.ir 88594014-15
CAUTION
Conditions
Each unit
90%RH or less (non-condensing)
A - 3
Servo motor
0 to 40 (non-freezing)
32 to 104 (non-freezing)
15 to 70 (non-freezing)
5 to 158 (non-freezing)
80%RH or less (non-condensing)
HC-KFS Series
HC-MFS Series
X Y : 49
HC-UFS13 to 43
HC-KFS Series
HC-MFS Series
X Y : 161
HC-UFS13 to 43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j2m- duMr-j2m-buMelservo-j2m series

Table of Contents