Table 6.3 Error Code List for AnUCPU (Continue)
Error
Error
Code
Massage
(D9008)
"LINK
47
PARA.
ERROR"
Detailed
Error
CPU
Code
States
(D9091)
471*
Continu
[When using
e
MELSECNET/10]
(1) The transfer source
(2) The specified range
(3) The specified range
472*
[When using
MELSECNET/10]
The contents of the
routing parameters
written from a
peripheral device differ
from the actual network
system.
128
Error and Cause
device range and
transfer destination
device range
specified for the
inter-network
transfer parameters
are in the same
network.
of transfer source
devices or transfer
destination devices
for the inter-network
transfer parameters
spans two or more
networks.
of transfer source
devices or transfer
destination devices
for the inter-network
transfer parameters
is not used by the
network.
Corrective Action
Write the network
parameters again and
check.
Write the routing
parameters again and
check.